Datasheet summary
Micropak NEXIS A Filter Elements
Engineering summary from PDF text extraction for Micropak NEXIS A Filter Elements. Verify every value with the OEM datasheet.
Summary
Product identification
The MICROPAK™NEXIS® A Series Filter Elements are depth filter elements featuring CoLD Fiber Technology. They are designed for use with reusable Micropak Cores.
Key features:
- Proprietary Filter System for use with Reusable Micropak Cores
- Continuous Gradient Pore Structure
- Melt Blown Micro-Fiber Filtration
- Excellent Chemical Compatibility
- All Polypropylene One Piece Construction
- Resists Contaminant Unloading Even at High Differential Pressure
- Absolute Rated at >99.9% Efficiency With Retention Ratings From 0.5 to 120 microns (µm)
- Element Free of Adhesives, Binders and Silicone
- Pressure Energized Gasket-to-Core Sealing System
Performance Specifications
- Filter Grades (>99.9% Retention Rating by ASTM F-795 Test): 0.5, 1, 3, 5, 10, 20, 30, 40, 50, 70, 90, 120 micron (µm)
Liquid Retention Ratings (µm):
| Cartridge Designation | 99.9% Efficiency | 90% Efficiency |
|---|---|---|
| MPNA 0.5 | 0.5 | < 0.5 |
| MPNA 1 | 1 | 1 |
| MPNA 3 | 3 | 2 |
| MPNA 5 | 5 | 4 |
| MPNA 10 | 10 | 5 |
| MPNA 20 | 19 | 13 |
| MPNA 30 | 27 | 18 |
| MPNA 40 | 36 | 20 |
| MPNA 50 | 46 | 27 |
| MPNA 70 | 65 | 42 |
| MPNA 90 | 85 | 55 |
| MPNA 120 | 105 | 65 |
Liquid retention ratings are based on Pall’s Dynamic Efficiency test protocol (single pass, destructive challenge test based on ASTM F795). Fine test dust is used for 0.5 to 20 micron range filters; coarse test dust for ratings above 20 micron.
Operating limits
- Recommended Change Out Differential Pressure: 35 psid (2.4 bard)
- Maximum Operating Temperature: 180˚F (82˚C)
Mechanical / hydraulic
- Materials of Construction:
- Filter Media: Polypropylene
- End Caps: Polypropylene
- Gaskets: Silicone Elastomer, Buna N, EPDM, Viton® A
- Dimensions (nominal):
- Outside Diameter: 2 3⁄5" (6.6 cm)
- Lengths:
- 9 3⁄4" (24.8 cm)
- 10" (25.4 cm)
- 19 1⁄2" (49.5 cm)
- 20" (50.8 cm)
- 29 1⁄4" (74.3 cm)
- 30" (76.2 cm)
- 39 1⁄2" (100.3 cm)
- 40" (102 cm)
Compliance
- FDA Listed Materials: Manufactured from materials listed by FDA for food contact applications per Title 21 of the U.S. Code of Federal Regulations.
- Toxicity: All polypropylene components (gaskets excluded) meet specifications for biological safety as per USP for Class VI-50˚C plastics.
Autoclaving
Multiple autoclaving for 30 minutes at 250˚F (121˚C) under no end load conditions is permitted, provided cores are inserted. Elements should be cooled to normal system operating temperatures prior to use. In-line steam sterilization is not recommended.
Flow Rate vs. Differential Pressure
Typical Flow vs. Differential Pressure curves are provided in the datasheet for application sizing, presented for water at 68˚F (20˚C).
- Graphs show flow rates (gpm, lpm) against differential pressure (psid, bar) for different micron ratings.
- One graph covers 0.5 µm to 20 µm.
- Another graph covers 30 µm to 120 µm. See the official PDF for exact tabulated values and graphical representations.
Ordering Information
The part number format is MPNA I – G N.
-
Code I - Filter Grades:
- 0.5: 0.5 µm
- 1: 1 µm
- 3: 3 µm
- 5: 5 µm
- 10: 10 µm
- 20: 20 µm
- 30: 30 µm
- 40: 40 µm
- 50: 50 µm
- 70: 70 µm
- 90: 90 µm
- 120: 120 µm
-
Code G - Element Lengths (nominal):
- 9.75: 9.75"
- 10: 10"
- 19.5: 19.5"
- 20: 20"
- 29.25: 29.25"
- 30: 30"
- 39.5: 39.5"
- 40: 40"
-
Code N - Gasket Materials:
- S: Silicone
- E: EPDM
- N: Buna N
- V: Viton A
For example, MPNA 20–10S would be a 20 µm filter element, 10" long, with a Silicone gasket.
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the original PDF datasheet. For contractual data, please refer to the specific OEM PDF revision used on your project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.