Datasheet summary
CW / WP Series Polypropylene Wound Cartridges
Engineering summary from PDF text extraction for CW / WP Series Polypropylene Wound Cartridges. Verify every value with the OEM datasheet.
Summary
Product identification
Pentek CW/WP Series polypropylene wound cartridges feature a string-wound design for reducing fine sediment from various fluids. They are an economical solution for removing silt, rust, and scale particles.
- CW cartridges: Economical, wound in a standard pattern around a polypropylene core.
- Nominal micron ratings: 10, 30, 50.
- WP Series cartridges: Wound in a precise pattern for greater surface area and higher dirt-loading capacity.
- Nominal micron ratings: 5, 30.
Operating limits
- Withstands temperatures up to 165ºF (73.9ºC).
- Temperature Rating: 40–145ºF (4.4–62.8ºC).
- Capable of flow rates between 7 and 10 GPM with minimal pressure drop.
Materials of Construction
- Filter Media: Polypropylene Fiber Cord
- Core: Polypropylene
Feed water
CW and WP Series cartridges are suitable for a wide variety of fluids, including municipal and well water.
WARNING: Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.
Mechanical / Hydraulic
Cartridge specifications and performance data:
- CW-F
- Maximum dimensions: 2¼" x 9⅞" (60 mm x 251 mm)
- Micron rating (nominal): 10
- Initial Δp: <1 psi @ 10 gpm (<0.07 bar @ 38 Lpm)
- CW-MF
- Maximum dimensions: 2¼" x 9⅞" (60 mm x 251 mm)
- Micron rating (nominal): 30
- Initial Δp: <1 psi @ 10 gpm (<0.07 bar @ 38 Lpm)
- CW-50
- Maximum dimensions: 2¼" x 9⅞" (60 mm x 251 mm)
- Micron rating (nominal): 50
- Initial Δp: <1 psi @ 10 gpm (<0.07 bar @ 38 Lpm)
- WP-5
- Maximum dimensions: 2¼" x 9⅞" (60 mm x 251 mm)
- Micron rating (nominal): 5
- Initial Δp: <2.5 psi @ 10 gpm (<0.17 bar @ 38 Lpm)
- WP-30
- Maximum dimensions: 2¼" x 9⅞" (60 mm x 251 mm)
- Micron rating (nominal): 30
- Initial Δp: <1.4 psi @ 10 gpm (<0.17 bar @ 38 Lpm)
Disclaimer: This summary is based on the provided text extract and may not include all figures, footnotes, or the latest revisions from the original OEM PDF datasheet. For contractual data, please refer to the specific OEM PDF revision used on your project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.