Datasheet summary
Microguard Series Cartridges
Engineering summary from PDF text extraction for Microguard Series Cartridges. Verify every value with the OEM datasheet.
Summary
Product identification
The MicroGuard™ Series comprises membrane filter cartridges designed for reliable bacteria and protozoan cyst reduction in drinking water without adding chemicals. They are suitable for Point-of-Use (POU) applications.
- MG-10MCB
- Carbon-Block/Membrane cartridge
- 10-inch nominal length microfilter (0.15 micron absolute rating)
- Uniquely designed with integral carbon block and sediment pre-filtration for chlorine taste and odor reduction and extended life.
- Features 2.5 times greater filtration surface area than some anti-microbial carbon blocks.
- MG-10T
- Triple Element cartridge (membrane only)
- 10-inch nominal length microfilter (0.15 micron absolute rating)
- Uniquely constructed with three membrane elements integrally sealed for higher flow rates and longer life.
- Life can be extended using PENTEK carbon block or sediment pre-filtration options.
- Common Features
- Absolute 0.15 micron particle retention for bacteria and protozoan cyst reduction.
- Utilizes patented highly asymmetric polyethersulfone membrane with proprietary hydrophilic formulation.
- Double O-ring end cap seals for absolute sealing in PENTEK Seal-Safe™ 3G housings.
- Effectiveness is not susceptible to common substances like hydrogen sulfide (H₂S), natural organic matter (NOM), and total dissolved solids (TDS).
- Not certified for sale in California, Iowa, Massachusetts, and Wisconsin.
- Not intended for converting wastewater or raw sewage into drinking water.
- Not intended for reducing pathogenic (disease-causing) virus particles.
- Intended for use on visually clear drinking water that meets all other public health standards.
Operating limits
- Water Temperature Range: 40-140°F (4.4-60°C)
- Pressure Differential: 88 psi (6.1 bar), max.
- Storage Temperature Range: 35-104°F (6.0-40°C)
- pH Range: 2-12
- Operating Pressure Range: 5-88 psi (0.35-6.1 bar), max.
- Water Turbidity: < 1 NTU
Feed water
The cartridges retain the natural mineral content of water and their protection is not susceptible to common substances in water like H₂S, NOM, and TDS.
WARNINGS:
- Do not use on water that may be contaminated by untreated surface water, water that may be contaminated by human or animal sewage, or other wastewater.
- These cartridges are not intended for reducing pathogenic (disease-causing) virus particles, if present in the water, to below safe levels.
- These cartridges are intended for use on visually clear drinking water that meets all other public health standards.
Product water
- Bacteria Reduction: > 99.9999% (> 6-Log), challenged with > 50,000,000 organisms per 100 mL. Organism: Brevundimonas diminuta (0.2 micron in size).
- Cyst Reduction: > 99.9999% (> 6-Log), challenged with > 1,000,000 microspheres per mL. Surrogate cyst procedure using 3.0 micron latex microspheres.
- Removes bacteria, cysts and other particles down to 0.15 micron in size.
Electrical
- No electrical power required (except for accessory pump, if needed for pressure).
- Protects even during power outages or intermittent power.
Mechanical / hydraulic
- Materials of Construction:
- Membrane: Polyethersulfone
- Membrane Assembly: Polystyrene, epoxy resin
- Carbon Pre-Filter (MG-10MCB only): Activated carbon with synthetic polymeric fibers and binders (Fibredyne™ technology)
- O-ring Seals: EPDM
- End Caps: Top: Polystyrene, Bottom: Polypropylene
- Netting: Bottom: Polyolefin (MG-10MCB only)
- Dimensions:
- MG-10MCB:
- Maximum diameter: 2.875" (73 mm)
- Maximum Length: 10.283" (261.18 mm)
- MG-10T:
- Maximum diameter: 3.000" (76 mm)
- Maximum Length: 10.294" (261.47 mm)
- MG-10MCB:
- Both models fit in PENTEK 3G housings, SlimLine®, and Standard housings.
- Requires only normal water line pressure to operate.
- No waste water or brine/concentrate flushing.
- Recommended Flow Rate:
- MG-10MCB: 1 gpm
- MG-10T: 3 gpm (The MG-10T is ideal for applications up to five gallons-per-minute)
- Initial ΔP @ Flow Rate:
- MG-10MCB: 11 psid @ 1 gpm (0.76 bar @ 3.8 lpm)
- MG-10T: 13 psid @ 3 gpm (0.9 bar @ 11.4 lpm)
- Estimated Capacities:
- MG-10MCB: 200-600 gallons (750-2,300 L)
- MG-10T: 600-1,800 gallons (2,300-6,800 L)
- Note: Capacities may vary depending on local water quality, type of pre-filtration, and acceptable minimum flow rate.
Applications
These cartridges are suitable for Point-of-Use (POU) applications including:
- Under sink, separate tap
- In-line (cold water line)
- Countertop
- Beverage dispensing
- Water for oral care, food preparation, hand washing
- Laboratories
- Photography/film
- Offices, restaurants
- Coffee makers (MG-10MCB)
- Process water (MG-10T)
Disclaimer: This summary is based solely on the provided text extract. It may not include all figures, footnotes, or the most recent revisions of the OEM PDF. Contractual data for specific projects must always match the exact OEM PDF revision used on that project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.