Datasheet summary
3M-MF-PP Q3 / 2
PDF datasheet mirror for 3M-MF-PP Q3 / 2 (3M Liqui-Flux Ultrafiltration). Verify with OEM before design.
Summary
Product identification
- 3M™ Capillary Membrane MF-PP Series, Type Q3/2
Mechanical / hydraulic
- Wall thickness: 200 ± 35 µm (7.9 ± 1.4 mil)
- Inner diameter: 600 ± 90 μm (23.6 ± 3.5 mil)
Membrane Performance Characteristics
- Bubble point (in isopropyl alcohol, 23 °C): ≥ 0.96 bar (≥ 13.9 psi)
- Transmembrane flow (isopropyl alcohol, 23 °C): ≥ 5.0 ml/(min cm² bar) (≥ 320.3 ml/(min ft² bar)) (≥ 2.2 ml/(min in² bar))
- Retention of bacteria (brevundimonas diminuta): ≥ 7 log reduction value
Chemical Composition
- Polymer: Polypropylene
- Residual oil content: ≤ 200 ppm
- Wetting property: Hydrophobic
Available Configurations
- Bundles (customer specified)
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the official PDF. Contractual data must always match the OEM PDF revision used on the project.