Datasheet summary
SFP 2860
PDF datasheet mirror for SFP 2860 (Dow UF Modules). Verify with OEM before design.
Summary
Product identification
- Models: DOW™ Ultrafiltration Modules SFP-2860 and SFD-2860
- Features:
- 0.03 µm nominal pore diameter for removal of bacteria, viruses, and particulates including colloids.
- PVDF polymeric hollow fibers for high strength and chemical resistance.
- Hydrophilic PVDF fibers for easy cleaning and wettability.
- Outside In flow configuration for high tolerance to feed solids.
- U-PVC housing.
- Application Suitability: Ideal for systems with capacities greater than 50 m³/hr (220 gpm). Suitable for surface water, seawater, industrial wastewaters, and secondary effluent wastewater.
- Module Dimensions: 8-inch diameter, 60-inch length.
- Product Specifications:
- SFP-2860 (Pretreatment, Part # 280933):
- Membrane area: 51 m² (549 ft²)
- Module volume: 35 Liters (9.3 Gallons)
- Weight (empty/water filled): 48/83 Kg (106/183 lbs)
- SFD-2860 (NSF/ANSI 61 Drinking water, Part # 324168):
- Membrane area: 51 m² (549 ft²)
- Module volume: 35 Liters (9.3 Gallons)
- Weight (empty/water filled): 48/83 Kg (106/183 lbs)
- SFP-2860 (Pretreatment, Part # 280933):
Mechanical / hydraulic
- Dimensions (refer to Figure 2 in the official PDF for detailed diagrams):
- Length (L): 1860 mm (73.2 inch)
- Length (L1): 1500 mm (59.1 inch)
- Length (L2): 1630 mm (64.2 inch)
- Length (L3): 1820 mm (71.7 inch)
- Diameter (D): 225 mm (8.9 inch)
- Width (W1): 180 mm (7.1 inch)
- Width (W2): 342 mm (13.5 inch)
- Flow configuration: Outside in, dead end flow
Operating limits
- Filtrate Flux @ 25ºC: 40-120 l/m²/hr (24-70 gfd)
- Flow range: 2.0 – 6.1 m³/hr (9.2 – 26.7 gpm)
- Temperature: 1-40ºC (34-104ºF)
- Max. inlet module pressure (@ 20ºC): 6.25 bar (93.75 psi)
- Max. operating TMP: 2.1 bar (30 psi)
- Max operating air scour flow: 12 nm³/hr (7.1 scfm)
- Max backwash pressure: 2.5 bar (36 psi)
- Operating pH: 2-11
- NaOCl (max.): 2,000 mg/L
- TSS (max.): 100 mg/L
- Turbidity (max.): 300 NTU
- Particle size (max.): 300 µ
Product water
- Expected filtrate turbidity: ≤0.1 NTU
- Expected filtrate SDI: ≤2.5
Important Notes
- Proper start-up of a UF system is essential to prepare membranes for operating service and prevent damage. Refer to the product technical manual.
- Avoid abrupt pressure variations during start-up, shutdown, cleaning, or other sequences.
- Flush the UF system to remove shipping solution and residual air prior to start-up.
- Target a permeate flow of 60% of design during initial operations. Permeate obtained from initial operations should be discarded depending on the application.
- Failure to strictly follow operating limits and guidelines may void the limited warranty.
- Preservative solution injection is recommended during system shutdowns to prevent biological growth.
- NSF/ANSI 61 certified drinking water modules require specific conditioning procedures prior to producing potable water and may be subject to additional regulatory restrictions.