Summary
Product identification
This document describes the DuPont™ Inge™ MB 1.5 XL 25 OP Module, designed for open platform systems.
Key Applications:
- Municipal wastewater
- Industrial water
- Wastewater reuse
- Ideal small size system
Key Features:
- Proven Multibore™ PES Fibers:
- Exceptional physical strength and chemical resistance.
- High colloidal particulate, bacteria and virus log removal rate.
- Unique design for high solids loads.
- Optional coagulation can enhance the removal of algae and organics.
- Optimized Module Design:
- Open platform design to fit customer built skids for height restricted or containerized filtration solution.
- Robust materials for long lifetime.
- Easy installation and low maintenance.
- All wetted parts corrosion free.
General Specifications:
- Part Number / GMID: IN-0071 / 12071519
- Mode of Filtration: In-Out Pressurized
- Membrane Type: Multibore™
- Membrane Material: PESm
- Nominal Membrane Pore Size: 0.02 µm
- Module Operating Process: Dead-end
- Housing Material: PVC-U, white
- End Cap Material: PVC-U, grey
- End Cap Coupling Material: SS (EPDM sealing)
Mechanical / hydraulic
Dimensions:
- Active Membrane Area: 25 m² (269 ft²)
- Module Length (L): 985 ± 1.5 mm (38.8 inch)
- Distance Top / Bottom Feed Port (L1): 1,099 ± 3.0 mm (43.3 inch)
- Length with End Caps (L2): 1,179 ± 3.0 mm (46.4 inch)
- Module Diameter (A): 250 ± 1.5 mm (9.8 inch)
- Distance Feed Top Port - Filtrate Port (B): 190 ± 1.5 mm (7.5 inch)
- Outer Diameter End Cap Coupling Maximum (C): 295 mm (11.6 inch)
- Protruding Part of the Port (E): 40 ± 1 mm (1.6 inch)
- Filtrate / Backwash Port (D): 50.8 mm (2 inch)
Weight and Volume:
- Shipping Weight: 32 kg (71 lbs.)
- Weight Empty: 32 kg (71 lbs.)
- Weight Filled: 67 kg (147 lbs.)
- Hold-Up Volume Feed (CIP): 15 L (3.9 gal)
- Hold-Up Volume Membrane Structure (CIP): 10 L (2.7 gal)
- Hold-Up Volume Filtrate (CIP): 16 L (4.2 gal)
Operating limits
Suggested Operating Conditions:
- Operating Temperature Range: 1 - 45 °C (34 - 113 °F)
- Operating pH: 2 - 12
- Cleaning pH: 1 - 13
- Typical Filtration TMP: 0.1 - 0.6 bar (1.5 - 8.7 psi)
- Typical Backwash TMP: 0.3 - 2.0 bar (4.4 - 29.0 psi)
- Backwash Flux: 230 L/(m²h) (135 gfd)
- Backwash Flow: 5.7 m³/h (25.1 gpm)
Maximum Operating Limits:
- Rate of Temperature Change: 5 °C/min (9 °F/min)
- Inlet Pressure at max 40°C: 5 bar (73 psi)
- Rate of Pressure Change: 0.5 bar/sec (7.3 psi/sec)
- Filtration TMP: 1.5 bar (22 psi)
- Backwash TMP: 3.0 bar (44 psi)
- Filtration Flux: 180 L/(m²h) (106 gfd)
- Filtration Flow: 4.5 m³/h (19.8 gpm)
- Backwash Flux: 300 L/(m²h) (176 gfd)
- Particle Size: 300 µm
- Exposure NaOCl*: ≤ 500,000 ppm x h (at pH ≥ 9.5)
- Concentration NaOCl: 2,000 ppm
- *NaOCl exposure limits at lower pH are dependent on water type and are project specific.
General Information:
- Avoid any abrupt pressure variations during start-up, operation, shutdown, cleaning or other sequences to prevent possible membrane damage. The maximum pressure change allowable is 0.5 bar/s.
- If operating limits and guidelines are not strictly followed, any warranty will be null and void.
- For assembly, preservation, and rinsing procedures, refer to specific DuPont™ Inge™ manuals.
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the original OEM PDF datasheet. Contractual data must always match the specific OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.