Back to DuPont Ultrafiltration
DuPont logo

Datasheet summary

Inge MB PRO XL 95 TR

PDF datasheet mirror for Inge MB PRO XL 95 TR (DuPont Ultrafiltration). Verify with OEM before design.

Summary

Product identification

  • Product Name: DuPont™ Inge™ MB PRO XL 95 TR Module
  • Part Number / GMID: IN-5122 / 12071531
  • Key Applications:
    • Municipal drinking water.
    • Desalination RO pretreatment.
    • Ideal for large systems.
  • Key Features:
    • Innovative Multibore™ PRO PES Fibers:
      • Exceptional physical strength and chemical resistance.
      • High colloidal particulate, bacteria and virus log removal rate.
      • Excellent filtration permeability.
      • Optional coagulation can enhance the removal of algae and organics.
    • Optimized Module Design:
      • Innovative end-cap design to suit T-Rack™ concept with simple assembly and scalability.
      • Enhanced active filtration area to minimize footprint.
      • Robust materials for long lifetime.
      • Easy installation and low maintenance.
      • All wetted parts corrosion free.
  • Mode of Filtration: In-Out Pressurized
  • Membrane Type: Multibore™ PRO
  • Membrane Material: PESm
  • Nominal Membrane Pore Size: 0.02 µm
  • Module Operating Process: Dead-end
  • Housing Material: PVC-U, white

Mechanical / hydraulic

  • Active Membrane Area: 95 m² (1,023 ft²)
  • Module Length Including T-Piece (L): 2,101 mm (82.7 inch)
  • Module Diameter (D): 250 mm (9.8 inch)
  • Shipping Weight (Module Only): 52 kg (115 lbs.)
  • Weight Empty (Module and Corresponding Frame): 65 kg (143 lbs.)
  • Weight Filled (Module and Corresponding Frame): 132 kg (291 lbs.)
  • Hold-Up Volume Feed (CIP): 32 L (8.4 gal)
  • Hold-Up Volume Membrane Structure (CIP): 18 L (4.8 gal)
  • Hold-Up Volume Filtrate (CIP): 35 L (9.3 gal)

Operating limits

  • Operating Temperature Range: 1 - 45 °C (34 - 113 °F)
  • Operating pH: 2 - 12
  • Cleaning pH: 1 - 13
  • Typical Filtration TMP: 0.1 - 0.6 bar (1.5 - 8.7 psi)
  • Typical Backwash TMP: 0.3 - 2.0 bar (4.4 - 29.0 psi)
  • Backwash Flux: 230 L/(m²h) (135 gfd)
  • Backwash Flow: 21.8 m³/h (96.0 gpm)
  • Maximum Rate of Temperature Change: 5 °C/min (9 °F/min)
  • Maximum Inlet Pressure at max 40°C: 5 bar (73 psi)
  • Maximum Rate of Pressure Change: 0.5 bar/sec (7.3 psi/sec)
  • Maximum Filtration TMP: 1.5 bar (22 psi)
  • Maximum Backwash TMP: 3.0 bar (44 psi)
  • Maximum Filtration Flux: 140 L/(m²h) (82 gfd)
  • Maximum Filtration Flow: 13.3 m³/h (58.6 gpm)
  • Maximum Backwash Flux: 250 L/(m²h) (147 gfd)
  • Maximum Particle Size: 230 µm
  • Exposure NaOCl: ≤ 500,000 ppm x h (at pH ≥ 9.5)
  • Concentration NaOCl: 2,000 ppm
    • Note: NaOCl exposure limits at lower pH are dependent on water type and are project specific.

General Information

The document provides detailed tables for T-Rack™ configurations, including single-sided and double-sided connections to manifolds, specifying the number of modules, T-Rack™ unit part numbers, lengths, and total membrane areas for various arrangements. See the official PDF for exact tabulated values.

  • Avoid any abrupt pressure variations during start-up, operation, shutdown, cleaning or other sequences to prevent possible membrane damage. The maximum pressure change allowable is 0.5 bar/s.
  • For assembly, refer to the latest version of the DuPont™ Inge™ TR Rack Assembly Manual (Form No. 45-D02230-en).
  • If operating limits and guidelines given in this bulletin are not strictly followed, any warranty will be null and void.
  • To control biological growth during extended system shutdowns, a storage solution must be introduced into the membrane modules. For detailed information, see the DuPont™ Inge™ PES-UF Module Preservation Instruction (Form No. 45-D02946-en).
  • Certified drinking water modules require specific conditioning procedures prior to producing potable water. For operating parameters, refer to the DuPont™ Inge™ Process and Design Guidelines (Form No. 45-D02234-en).
  • Drinking water modules may be subjected to additional regulatory restrictions in some countries. Check local regulatory guidelines and application status before use.
  • Flushing needs to be done according to the DuPont™ Inge™ PES-UF Module Rinsing Procedure (Form No. 45-D02947-en).

Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the original PDF datasheet. Contractual data must always match the OEM PDF revision used on the project.

Official datasheet (PDF)

Lenntech datasheet mirror

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.