Datasheet summary
MB Pro 95
PDF datasheet mirror for MB Pro 95 (DuPont Ultrafiltration). Verify with OEM before design.
Summary
Product identification
- Product Name: DuPont™ IntegraTec™ MB PRO 95
- Part Number: IN-0122
- Module Series: P series | Pressurized PES UF Module
- Form Number: 45-D04342-en, Rev. 1, July 2023
- Mode of Filtration: In-Out Pressurized
- Membrane Type: Multibore™ PRO
- Membrane Material: PESm
- Nominal Membrane Pore Size: 0.02 µm
- Module Operating Process: Dead-end
- Housing Material: PVC-U, white
- End Cap Material: PVC-U, grey
- End Cap Coupling Material: SS (EPDM sealing)
Key Applications
- Municipal drinking water
- Desalination RO pretreatment
- Ideal for large systems
Key Features
Innovative Multibore™ PRO PES Fibers:
- Exceptional physical strength and chemical resistance.
- High colloidal particulate, bacteria and virus log removal rate.
- Excellent filtration permeability.
- Optional coagulation can enhance the removal of algae and organics.
Optimized Module Design:
- Open platform design to fit customer built skids.
- Enhanced active filtration area to minimize footprint.
- Robust materials for long lifetime.
- Easy installation and low maintenance.
- All wetted parts corrosion free.
Mechanical / hydraulic
- Active Membrane Area: 95 m² (1,023 ft²)
- Module Length (L): 1,720 ± 1.5 mm (67.7 inch)
- Distance Top / Bottom Feed Port (L1): 1,834 ± 3.0 mm (72.2 inch)
- Length with End Caps (L2): 1,914 ± 3.0 mm (75.4 inch)
- Module Diameter (A): 250 ± 1.5 mm (9.8 inch)
- Distance Feed Top Port - Filtrate Port (B): 190 ± 1.5 (7.5 inch)
- Outer Diameter End Cap Coupling Maximum (C): 295 mm (11.6 inch)
- Protruding Part of the Port (E): 40 ± 1 mm (1.6 inch)
- Filtrate / Backwash Port (D): 50.8 mm (2 inch)
- Shipping Weight: 58 kg (128 lbs.)
- Weight Empty: 58 kg (128 lbs.)
- Weight Filled: 110 kg (243 lbs.)
- Hold-Up Volume Feed (CIP): 22 L (5.7 gal)
- Hold-Up Volume Membrane Structure (CIP): 18 L (4.8 gal)
- Hold-Up Volume Filtrate (CIP): 21 L (5.4 gal)
Operating limits
Suggested Operating Conditions:
- Operating Temperature Range: 1 - 40 °C (34 - 104 °F)
- Operating pH: 3 - 11
- Cleaning pH: 1 - 13
- Typical Filtration TMP: 0.1 - 0.6 bar (1.5 - 8.7 psi)
- Typical Backwash TMP: 0.3 - 2.0 bar (4.4 - 29.0 psi)
- Backwash Flux: 230 L/(m²h) (135 gfd)
- Backwash Flow: 21.8 m³/h (96.0 gpm)
Operating Limits (Maximum):
- Rate of Temperature Change: 5 °C/min (9 °F/min)
- Inlet Pressure (20 - 40 °C): 5 bar (73 psi)
- Rate of Pressure Change: 0.5 bar/sec (7.3 psi/sec)
- Filtration TMP: 1.5 bar (22 psi)
- Backwash TMP: 3.0 bar (44 psi)
- Filtration Flux: 140 L/(m²h) (82 gfd)
- Filtration Flow: 13.3 m³/h (58.6 gpm)
- Backwash Flux: 250 L/(m²h) (147 gfd)
- Particle Size: 230 µm
- Exposure NaOCl: ≤ 250,000 ppm x h (at pH ≥ 9.5)
- Concentration NaOCl: 500 ppm
Important Notes
- Avoid any abrupt pressure variations during start-up, operation, shutdown, cleaning or other sequences to prevent possible membrane damage. The maximum pressure change allowable is 0.5 bar/s.
- If operating limits and guidelines given in this bulletin are not strictly followed, any warranty will be null and void.
- To control biological growth during extended system shutdowns, a storage solution must be introduced into the membrane modules.
- Certified drinking water modules require specific conditioning procedures prior to producing potable water.
- Drinking water modules may be subjected to additional regulatory restrictions in some countries. Please check local regulatory guidelines and application status before use.