Back to DuPont Ultrafiltration
DuPont logo

Datasheet summary

XP 77 IP

PDF datasheet mirror for XP 77 IP (DuPont Ultrafiltration). Verify with OEM before design.

Summary

Product identification

  • Product Name: DuPont™ IntegraTec™ XP 77 IP P series Pressurized PVDF UF Module
  • Previous Name: DuPont™ IntegraPac™ IPD-77XP
  • Part Number / GMID: 12091629
  • Mode of Filtration: Out-In Pressurized
  • Membrane Type: Hollow fiber
  • Membrane Material: PVDF (Polyvinylidene Fluoride)
  • Membrane Pore Size: 0.03 μm
  • Module Operating Process: Dead-end
  • Other Wetted Module Components: Polyurethane, uPVC, EPDM, and ABS

Mechanical / hydraulic

  • Active Membrane Area: 77 m² (829 ft²)
  • Module Length Overall (L): 2,488 ± 3.0 mm (98.0 ± 0.1 inch)
  • Module Length (L3): 2,364 ± 3.0 mm (93.1 ± 0.1 inch)
  • Module Length (L2): 2,189 ± 3.0 mm (86.2 ± 0.1 inch)
  • Module Length (L1): 2,000 ± 3.0 mm (78.7 ± 0.1 inch)
  • Module Diameter (D): 225 mm (8.9 inch)
  • Module Width (W1): 360 mm (14.2 inch)
  • Module Width (W2): 342 mm (13.5 inch)
  • Shipping Weight: 81 kg (178 lbs.)
  • Weight Empty: 66 kg (146 lbs.)
  • Weight Filled: 119 kg (262 lbs.)
  • Hold-Up Volume Feed (CIP): 38 L (10.0 gal)
  • Hold-Up Volume Membrane Structure (CIP): 14 L (3.7 gal)
  • Hold-Up Volume Filtrate (CIP): 12 L (3.2 gal)

Operating limits

  • Operating Temperature Range: 1 - 40 °C (34 - 104 °F)
  • Operating pH: 2 - 11
  • Cleaning pH: 2 - 12
  • Typical Filtration Trans-Membrane Pressure (TMP): 0.4 - 1.5 bar (5.8 - 21.8 psi)
  • Typical Backwash TMP: 0.6 - 2.0 bar (8.7 - 29.0 psi)
  • Backwash Type: Air scour with liquid backwash
  • Backwash Flux: 100 L/(m²h) (58.8 gfd)
  • Backwash Flow: 7.7 m³/h (34.0 gpm)
  • Maximum Rate of Pressure Change: 0.5 bar/sec (7.3 psi/sec)
  • Maximum Inlet Pressure: 6.25 bar (at 20 °C) (90.7 psi)
  • Maximum Filtration TMP: 2.1 bar (30.5 psi)
  • Maximum Backwash TMP: 2.5 bar (36 psi)
  • Maximum Filtration Flux: 110 L/(m²h) (64.5 gfd)
  • Maximum Filtration Flow: 8.5 m³/h (37.4 gpm)
  • Maximum Backwash Flux: 120 L/(m²h) (70.6 gfd)
  • Maximum Particle Size: 300 μm
  • Maximum Exposure NaOCl: ≤1,500,000 ppm x h
  • Recommended Maximum Instantaneous Exposure NaOCl: 2,000 ppm

Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the official PDF datasheet. Contractual data must always match the specific OEM PDF revision used for the project.