Datasheet summary
IP-77 / IPD-77 6-22 modules
PDF datasheet mirror for IP-77 / IPD-77 6-22 modules (DuPont Ultrafiltration). Verify with OEM before design.
Summary
Product identification
- Product: IntegraPac™ Ultrafiltration Skid with IP-77 or IPD-77 modules
- Description: A pre-engineered, standardized skid design from DuPont Water Solutions, consisting of IntegraPac™ ultrafiltration modules, auxiliary parts, and piping. It is designed to streamline design, assembly, and installation, offering lower skid costs, reduced engineering design costs, easy assembly, a smaller footprint, and a shortened delivery schedule.
- Features:
- IP-77 and IPD-77 skids are tested and certified by NSF International under NSF/ANSI Standard 61, ensuring safe use in drinking water applications.
- NSF/ANSI Standard 419 for Public Drinking Water Equipment on module IPD-77.
- Direct coupling of modules eliminates ancillary piping, saving costs and reducing footprint.
- Modular and scalable for design across a wide range of flow rates.
- Materials of construction selected for corrosion resistance and chemical compatibility.
- Shipped unassembled to lower transportation cost and help prevent damage in transit.
- Standardized and pre-fabricated components eliminate measuring, cutting, gluing, and welding.
- Easily accessible for physical inspection or replacement at end of life.
- Operator-friendly transparent filtrate elbow designed and located for easy visual integrity inspection.
- High pressure rating to enable direct feed to reverse osmosis feed pumps.
Typical Properties
| No. of Modules | IntegraPac™ Skid | Membrane Area (m²) | Membrane Area (ft²) | Flow @ 65 lmh (m³/h) | Flow @ 65 lmh (gpm) | Length (L) (mm) | Length (L) (ft) | Width (W) (mm) | Width (W) (ft) | Height (H) (mm) | Height (H) (ft) | Weight, dry (incl. modules) (kg) | Weight, dry (incl. modules) (lbs) | Weight, filled (incl. modules) (kg) | Weight, filled (incl. modules) (lbs) | Hold-Up Volume (m³) | Hold-Up Volume (US gal) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 6 | IP & IPD- 77-06 | 462 | 4974 | 30 | 132 | 1241 | 4.1 | 764 | 2.51 | 2875 | 9.43 | 496 | 1093 | 840 | 1852 | 0.32 | 84.0 |
| 8 | IP & IPD- 77-08 | 616 | 6632 | 40 | 176 | 1604 | 5.3 | 764 | 2.51 | 2875 | 9.43 | 644 | 1420 | 1102 | 2429 | 0.42 | 112.0 |
| 10 | IP & IPD- 77-10 | 770 | 8290 | 50 | 220 | 1967 | 6.5 | 764 | 2.51 | 2875 | 9.43 | 791 | 1744 | 1364 | 3007 | 0.53 | 140.0 |
| 12 | IP & IPD- 77-12 | 924 | 9948 | 60 | 264 | 2330 | 7.6 | 764 | 2.51 | 2875 | 9.43 | 939 | 2070 | 1626 | 3585 | 0.64 | 168.0 |
| 14 | IP & IPD- 77-14 | 1078 | 11606 | 70 | 309 | 2693 | 8.8 | 764 | 2.51 | 2875 | 9.43 | 1091 | 2405 | 1893 | 4173 | 0.74 | 196.0 |
| 16 | IP & IPD- 77-16 | 1232 | 13264 | 80 | 353 | 3056 | 10.0 | 764 | 2.51 | 2875 | 9.43 | 1249 | 2754 | 2165 | 4773 | 0.85 | 224.0 |
| 18 | IP & IPD- 77-18 | 1386 | 14922 | 90 | 397 | 3419 | 11.2 | 764 | 2.51 | 2875 | 9.43 | 1401 | 3089 | 2432 | 5362 | 0.95 | 252.0 |
| 20 | IP & IPD- 77-20 | 1540 | 16580 | 100 | 441 | 3782 | 12.4 | 764 | 2.51 | 2875 | 9.43 | 1554 | 3426 | 2699 | 5950 | 1.06 | 280.0 |
| 22 | IP & IPD- 77-22 | 1694 | 18238 | 110 | 485 | 4145 | 13.6 | 764 | 2.51 | 2875 | 9.43 | 1706 | 3761 | 2966 | 6539 | 1.17 | 308.0 |
Operating limits
- Filtrate Flux (25ºC): 40-90 l/m²/hr (24 - 53 gfd)
- Temperature: 1-40ºC (34-104ºF)
- Maximum Inlet Module Pressure (20ºC): 6.25 bar (90.65 psi)
- Maximum Inlet Module Pressure (40ºC): 4.75 bar (68.89 psi)
- Maximum Operating TMP: 2.1 bar (30.5 psi)
- Maximum Operating Air Scour Flow: 12 nm³/hr (7.1 scfm)
- Maximum Backwash Pressure: 2.5 bar (36 psi)
- Operating pH: 2 – 11
- Maximum NaOCl: 2,000 mg/L
- Maximum Particle Size: 300 µm
- Flow Configuration: Outside in, dead end flow
Product water
- Expected Filtrate Turbidity: ≤0.1 NTU
- Expected Filtrate SDI: ≤2.5
- Note on cyst and pathogen removal: The use of this product in and of itself does not necessarily guarantee the removal of cysts and pathogens from water. Effective cyst and pathogen reduction is dependent on the complete system design and on the operation and maintenance of the system.
- Regulatory Note: NSF/ANSI 61 and 419 certified drinking water modules require specific conditioning procedures prior to producing potable water. Refer to the Ultrafiltration Technical Manual for specific procedures.
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the official PDF. Contractual data must always match the OEM PDF revision used on the project.