Datasheet summary
IMT 10060 UF-MB
PDF datasheet mirror for IMT 10060 UF-MB (IMT Ultrafiltration). Verify with OEM before design.
Summary
Product identification
- Ultrafiltration element: 10060 UF/MB
- Revision: September 2010
Mechanical / hydraulic
- Material housing: PVC
- Material endcap: GFR-Polyamide
- Housing length: 1500 +0 /-4 mm (59 inch)
- Element length: 1682 +/- 1,5 mm (66 inch)
- Distance feed connectors: 1596 +/- 1,5 mm (63 inch)
- Distance feed element center: 179 +/- 1,0 mm (7 inch)
- Distance feed-permeate connector: 191 +/- 1,0 mm (8 inch)
- Permeate connection OD: 2" victaulic
- Feed connection OD: 2" victaulic
- Housing OD: 250 mm (10 inch)
- Element OD at endcap: 320 mm (13 inch)
- Weight: 31 kg (68 lbs)
Membrane
- Material: PES
- Type: SevenBore®
- Diameter bores ID: 0,9 mm (0,04 inch)
- Diameter fiber OD: 4,0 mm (0,16 inch)
- MWCO: 100-150 kD
- Area: 50 m² (538 ft²)
Operating limits
- Maximum operating temperature: 40 °C (104 °F)
- Maximum system pressure: 7,5 bar (109 psi)
- Trans membrane pressure:
- Operation: < 1,0 bar (< 14,5 psi)
- Maximum: 2,5 bar (36 psi)
- Productivity:
- Clean water at 25°C (77°F): 800 to 1000 l/m² barh (32 to 41 gfd/psi)
- Process: 70 to 120 l/m²h (42 to 72 gfd)
- Backwash/forward flush: 250 l/m²h (150 gfd)
- Permeate flow at 100 l/m² h: 5 m³ (22 gpm)
- pH range during operation: 3-10
Cleaning
- Soaking time during cleaning: min 5 min
- pH range during cleaning: 1-13
- Disinfecting chemicals:
- Hypochlorite (NaOCl): 50-200 ppm
- Hydrogen peroxide (H₂O₂): 100-200 ppm
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the official PDF. Contractual data must always match the specific OEM PDF revision used for the project.