Datasheet summary
IMT 4150 UF-MB-TAP
PDF datasheet mirror for IMT 4150 UF-MB-TAP (IMT Ultrafiltration). Verify with OEM before design.
Summary
Product identification
- Product Type: Ultrafiltration element
- Model: 4150 UF/MB/TAP
Mechanical / hydraulic
- Housing Material: PVC
- Connector Material: PVC
- Housing Length: 1500 mm (59 inch) ± 2.0
- Element Length: 1700 mm (67 inch) ± 3.0
- Element length (without screw ends): 1642 mm (65 inch) ± 3.0
- Distance Permeate Connector-Feed Connector: 265 mm (10 inch) ± 2.0
- Distance Permeate Connector-Feed Connector (without screw ends): 236 mm (9 inch) ± 2.0
- Distance Permeate Connector-Element Center: 90 mm (4 inch) ± 2.0
- Permeate Connection Male OD: 1"
- Feed Connection Male OD: 1"
- Housing OD: 110 mm (4 inch)
- Element OD: 125 mm (5 inch)
- Endcaps ID (without screw ends): 32 mm (1 inch)
- Weight: 6.3 kg (14 lbs)
Membrane Type
- Material: PES
- Type: SevenBore®
- Diameter Bores ID: 0.9 mm (0.04 inch)
- Diameter Fiber OD: 4.0 mm (0.16 inch)
- MWCO: 100-150 kD
- Area: 9 m² (97 ft²)
Operating limits
- Maximum Operating Temperature: 40 °C (104 °F)
- Maximum System Pressure: 10 bar (145 psi)
- Transmembrane Pressure:
- Operation: < 1.0 bar (< 14.5 psi)
- Maximum: 2.5 bar (36 psi)
- pH Range During Operation: 3-10
Product water
- Productivity (clean water at 25°C / 77°F): 1300-1600 l/m²barh (53-65 gfd/psi)
- Productivity (process): 100 to 350 l/m²h (60 to 210 gfd)
- Productivity (backwash/forward flush): 250 l/m²h (150 gfd)
- Permeate Flow at 100 l/m²h: 900 l/h (4 gpm)
Cleaning
- Soaking Time During Cleaning: min 5 min
- pH Range During Cleaning: 1-13
- Disinfecting Chemicals:
- Hypochlorite (NaOCl): 50-200 ppm
- Hydrogen peroxide (H₂O₂): 100-200 ppm
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the official OEM PDF datasheet. Contractual data must always match the specific OEM PDF revision used for the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.