Summary

Product Identification

  • Product Name: 6100 UF/MB/TAP
  • Product Type: Ultrafiltration element
  • Revision Date: February 2011 (supersedes September 2010)

Mechanical / Hydraulic

  • Material Housing: PVC
  • Material Connector: PVC
  • Housing Length: 1000 mm (± 2.0) / 30 inch
  • Element Length: 1253 mm (± 3.0) / 37 inch
  • Element Length (without screw ends): 1185 mm (± 3.0) / 35 inch
  • Distance Permeate Connector-Feed Connector: 290 mm (± 2.0) / 10 inch
  • Distance Permeate Connector-Feed Connector (without screw ends): 256 mm (± 2.0) / 9 inch
  • Distance Permeate Connector-Element Center: 111 mm (± 2.0) / 0 inch
  • Permeate Connection Male OD: 1½"
  • Feed Connection Male OD: 1½"
  • Housing OD: 140 mm / 6 inch
  • Element OD: 160 mm / 6 inch
  • Endcaps ID (without screw ends): 50 mm / 2 inch
  • Weight: 9.8 kg / 22 lbs
  • Note: Screw ends are provided separately.

Membrane Specifications

  • Membrane Material: PES
  • Membrane Type: SevenBore®
  • Diameter Bores ID: 0.9 mm / 0.04 inch
  • Diameter Fiber OD: 4.0 mm / 0.16 inch
  • MWCO: 100-150 kD
  • Active Area: 12 m² / 129 ft²

Operating Limits

  • Maximum Operating Temperature: 40 °C (104 °F)
  • Maximum System Pressure: 10 bar (145 psi)
  • Transmembrane Pressure (Operation): < 1.0 bar (< 14.5 psi)
  • Transmembrane Pressure (Maximum): 2.5 bar (36 psi)
  • pH Range (Operation): 3-10

Product Water Characteristics

  • Productivity (Clean Water at 25 °C / 77 °F): 1300-1600 l/m²barh (53-65 gfd/psi)
  • Productivity (Process): 100 to 350 l/m²h (60 to 210 gfd)
  • Productivity (Backwash/Forward Flush): 250 l/m²h (150 gfd)
  • Permeate Flow (at 100 l/m²h): 1.2 m³ (5 gpm)

Cleaning

  • Soaking Time During Cleaning: Minimum 5 min
  • pH Range During Cleaning: 1-13
  • Disinfecting Chemicals:
    • Hypochlorite (NaOCl): 50-200 ppm
    • Hydrogen Peroxide (H₂O₂): 100-200 ppm

Disclaimer