
Datasheet summary
IMT 8060 UF-MB-RX
PDF datasheet mirror for IMT 8060 UF-MB-RX (IMT Ultrafiltration). Verify with OEM before design.
Summary
Product identification
- Ultrafiltration element: 8060/UF/MB/RX
Mechanical / hydraulic
- Element data
- Material housing: PVC
- Housing length: 1527 mm +/- 1,0 (60 inch)
- Permeate connection ID: 42,6 mm +/- 0,5 (2 inch)
- Element OD: 200 mm (8 inch)
- Weight: 19 kg (42 lbs)
- Membrane data
- Material: PES
- Type: SevenBore®
- Diameter bores ID: 0,8 mm (0,03 inch)
- Diameter fiber OD: 3,6 mm (0,14 inch)
- MWCO: 100-150 kD
- Area: 40 m² (431 ft²)
Operating limits
- Maximum operating temperature: 40 °C (104 °F)
- Maximum system pressure: 7,5 bar (109 psi)
- Trans membrane pressure:
- operation: < 1,0 bar (< 14,5 psi)
- maximum: 2,5 bar (36 psi)
- Productivity:
- clean water at 25° C (77°F): 800 to 1000 l/m²barh (32 to 41 gfd/psi)
- process: 50 to 120 l/m²h (30 to 72 gfd)
- backwash/forward flush: 250 l/m²h (150 gfd)
- Permeate flow at 100 l/m² h: 4 m³ (18 gpm)
- pH range during operation: 3-10
Cleaning
- Soaking time during cleaning: min 5
- pH range during cleaning: 1-13
- Disinfecting chemicals:
- hypochlorite (NaOCl): 50-200 ppm
- hydrogenperoxide (H₂O₂): 100-200 ppm
Disclaimer: This summary is based on extracted text and may miss figures, footnotes, or recent revisions present in the official PDF. Contractual data must always match the OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.