Datasheet summary
MEMCOR Pressurized Membranes
PDF datasheet mirror for MEMCOR Pressurized Membranes (MEMCOR Ultrafiltration). Verify with OEM before design.
Summary
MEMCOR® Pressurised and Submerged membrane modules are designed for a wide range of applications.
Performance values presented are typical only and do not represent a performance guarantee. Performance guarantees for any project apply only when confirmed in writing by Memcor Australia Pty Ltd with specific reference to the project in question.
Product identification
MEMCOR® modules are available in Pressurised and Submerged configurations.
General Parameters for all listed modules:
- Membrane Material: PVDF
- Backwash Type: Air Scour Liquid B/W
- Nominal Pore Size: 0.04 µm
MEMCOR® Pressurised Membranes:
- Module Models: L10V, L10U, L20V
- Typical Applications:
- L10V, L20V: General Applications
- L10U: High Solids & General Applications
MEMCOR® Submerged Membranes:
- Module Models: S10V, S10U
- Typical Applications:
- S10V: General Applications
- S10U: High Solids & General Applications
Operating limits
- Maximum Temperature: 45 °C (all models)
- pH Range: 2-10 (all models)
- Average Free Chlorine: < 5 ppm (all models)
- Maximum Free Chlorine:
- Pressurised Modules (L10V, L10U, L20V): 1000 ppm
- Submerged Modules (S10V, S10U): 200 ppm
Mechanical / hydraulic
MEMCOR® Pressurised Membranes
- L10V:
- Surface Area: 23.4 m²
- Module Weight Wet: 6.5 kg
- Nominal Module Length: 1157 mm
- Nominal Module Diameter: 119 mm
- L10U:
- Surface Area: 18.7 m²
- Module Weight Wet: 6.0 kg
- Nominal Module Length: 1157 mm
- Nominal Module Diameter: 119 mm
- L20V:
- Surface Area: 38.1 m²
- Module Weight Wet: 9.0 kg
- Nominal Module Length: 1800 mm
- Nominal Module Diameter: 119 mm
MEMCOR® Submerged Membranes
- S10V:
- Surface Area: 27.9 m²
- Module Weight Wet: 6.7 kg
- Nominal Module Length: 1186 mm
- Nominal Module Diameter: 131 mm
- S10U:
- Surface Area: 22.1 m²
- Module Weight Wet: 5.0 kg
- Nominal Module Length: 1186 mm
- Nominal Module Diameter: 131 mm
Performance Characteristics
Performance values are typical and depend on feed water quality.
MEMCOR® Pressurised Membranes
- L10V:
- Chlorinated Secondary Effluent: 30.3 kL/day, 93% Recovery
- Clear Surface Water: 38.5 kL/day, 95% Recovery
- Turbid Surface Water: 30.3 kL/day, 94% Recovery
- Sea Water: 35.7 kL/day, 95% Recovery
- Chlorinated Municipal Water: 55.0 kL/day, > 96% Recovery
- L10U:
- Turbid Surface Water: 24.2 kL/day, 93% Recovery
- Surface Water - with Algae or coagulant: 26.3 kL/day, 93% Recovery
- L20V:
- Chlorinated Secondary Effluent: 49.4 kL/day, 94% Recovery
- Clear Surface Water: 62.7 kL/day, 96% Recovery
- Turbid Surface Water: 49.4 kL/day, 94% Recovery
- Sea Water: 58.3 kL/day, 95% Recovery
- Chlorinated Municipal Water: 89.5 kL/day, > 96% Recovery
MEMCOR® Submerged Membranes
- S10V:
- Chlorinated Secondary Effluent: 32.9 kL/day, 94% Recovery
- Clear Surface Water: 39.2 kL/day, 96% Recovery
- Turbid Surface Water: 32.9 kL/day, 94% Recovery
- Sea Water: 39.2 kL/day, 95% Recovery
- Chlorinated Municipal Water: 52.4 kL/day, 96% Recovery
- S10U:
- Turbid Surface Water: 26.1 kL/day, 93% Recovery
- Surface Water - with Algae or coagulant: 28.7 kL/day, 94% Recovery
Feed water
The specifications above give indicative performance for a range of water sources. The characteristics of these water sources are tabulated below:
| Water Type | Turbidity (NTU) | SS (mg/L) | BOD (mg/L) | TOC (mg/L) | Ammonia (mg/L) | Coag. (mg/L) | Total Chlorine (mg/L) | Free Chlorine (mg/L) |
|---|---|---|---|---|---|---|---|---|
| Chlorinated Secondary Effluent | < 10 | < 50 | 20 | N/A | > 3 | Nil | 1 - 3 | Nil |
| Clear Surface Water | < 10 | 1 | N/A | < 2 | N/A | Nil | Nil | Nil |
| Turbid Surface Water | 10 - 100 | < 100 | N/A | < 10 | N/A | < 5 | Nil | Nil |
| Surface Water with Algae or Coagulant | 100 - 200 | < 100 | N/A | < 15 | N/A | 5 - 20 | Nil | Nil |
| Sea Water | 10 - 40 | 10 - 30 | N/A | < 2 | N/A | Nil | < 2 | < 2 |
| Chlorinated Municipal Water | < 1 | 0.1 | N/A | < 1 | N/A | Nil | < 2 | < 2 |
Contact Memcor Australia for advice on treatment of feed waters that are outside the range of qualities given above, or where performance guarantees are required.
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the original OEM PDF datasheet. Contractual data must always match the specific OEM PDF revision used on the project.
Official datasheet (PDF)