MEMCOR® Pressurised and Submerged membrane modules are designed for a wide range of applications.

Performance values presented are typical only and do not represent a performance guarantee. Performance guarantees for any project apply only when confirmed in writing by Memcor Australia Pty Ltd with specific reference to the project in question.

Product identification

MEMCOR® modules are available in Pressurised and Submerged configurations.

General Parameters for all listed modules:

  • Membrane Material: PVDF
  • Backwash Type: Air Scour Liquid B/W
  • Nominal Pore Size: 0.04 µm

MEMCOR® Pressurised Membranes:

  • Module Models: L10V, L10U, L20V
  • Typical Applications:
    • L10V, L20V: General Applications
    • L10U: High Solids & General Applications

MEMCOR® Submerged Membranes:

  • Module Models: S10V, S10U
  • Typical Applications:
    • S10V: General Applications
    • S10U: High Solids & General Applications

Operating limits

  • Maximum Temperature: 45 °C (all models)
  • pH Range: 2-10 (all models)
  • Average Free Chlorine: < 5 ppm (all models)
  • Maximum Free Chlorine:
    • Pressurised Modules (L10V, L10U, L20V): 1000 ppm
    • Submerged Modules (S10V, S10U): 200 ppm

Mechanical / hydraulic

MEMCOR® Pressurised Membranes

  • L10V:
    • Surface Area: 23.4 m²
    • Module Weight Wet: 6.5 kg
    • Nominal Module Length: 1157 mm
    • Nominal Module Diameter: 119 mm
  • L10U:
    • Surface Area: 18.7 m²
    • Module Weight Wet: 6.0 kg
    • Nominal Module Length: 1157 mm
    • Nominal Module Diameter: 119 mm
  • L20V:
    • Surface Area: 38.1 m²
    • Module Weight Wet: 9.0 kg
    • Nominal Module Length: 1800 mm
    • Nominal Module Diameter: 119 mm

MEMCOR® Submerged Membranes

  • S10V:
    • Surface Area: 27.9 m²
    • Module Weight Wet: 6.7 kg
    • Nominal Module Length: 1186 mm
    • Nominal Module Diameter: 131 mm
  • S10U:
    • Surface Area: 22.1 m²
    • Module Weight Wet: 5.0 kg
    • Nominal Module Length: 1186 mm
    • Nominal Module Diameter: 131 mm

Performance Characteristics

Performance values are typical and depend on feed water quality.

MEMCOR® Pressurised Membranes

  • L10V:
    • Chlorinated Secondary Effluent: 30.3 kL/day, 93% Recovery
    • Clear Surface Water: 38.5 kL/day, 95% Recovery
    • Turbid Surface Water: 30.3 kL/day, 94% Recovery
    • Sea Water: 35.7 kL/day, 95% Recovery
    • Chlorinated Municipal Water: 55.0 kL/day, > 96% Recovery
  • L10U:
    • Turbid Surface Water: 24.2 kL/day, 93% Recovery
    • Surface Water - with Algae or coagulant: 26.3 kL/day, 93% Recovery
  • L20V:
    • Chlorinated Secondary Effluent: 49.4 kL/day, 94% Recovery
    • Clear Surface Water: 62.7 kL/day, 96% Recovery
    • Turbid Surface Water: 49.4 kL/day, 94% Recovery
    • Sea Water: 58.3 kL/day, 95% Recovery
    • Chlorinated Municipal Water: 89.5 kL/day, > 96% Recovery

MEMCOR® Submerged Membranes

  • S10V:
    • Chlorinated Secondary Effluent: 32.9 kL/day, 94% Recovery
    • Clear Surface Water: 39.2 kL/day, 96% Recovery
    • Turbid Surface Water: 32.9 kL/day, 94% Recovery
    • Sea Water: 39.2 kL/day, 95% Recovery
    • Chlorinated Municipal Water: 52.4 kL/day, 96% Recovery
  • S10U:
    • Turbid Surface Water: 26.1 kL/day, 93% Recovery
    • Surface Water - with Algae or coagulant: 28.7 kL/day, 94% Recovery

Feed water

The specifications above give indicative performance for a range of water sources. The characteristics of these water sources are tabulated below:

Water TypeTurbidity (NTU)SS (mg/L)BOD (mg/L)TOC (mg/L)Ammonia (mg/L)Coag. (mg/L)Total Chlorine (mg/L)Free Chlorine (mg/L)
Chlorinated Secondary Effluent< 10< 5020N/A> 3Nil1 - 3Nil
Clear Surface Water< 101N/A< 2N/ANilNilNil
Turbid Surface Water10 - 100< 100N/A< 10N/A< 5NilNil
Surface Water with Algae or Coagulant100 - 200< 100N/A< 15N/A5 - 20NilNil
Sea Water10 - 4010 - 30N/A< 2N/ANil< 2< 2
Chlorinated Municipal Water< 10.1N/A< 1N/ANil< 2< 2

Contact Memcor Australia for advice on treatment of feed waters that are outside the range of qualities given above, or where performance guarantees are required.