Back to Microdyn-Nadir UF
MANN+HUMMEL logo

Datasheet summary

Aquadyn UA1060

PDF datasheet mirror for Aquadyn UA1060 (Microdyn-Nadir UF). Verify with OEM before design.

Summary

Product identification

  • Product name: AQUADYN® UA1060
  • Filtration type: Ultrafiltration
  • Membrane type: Hollow fiber
  • Membrane structure: Double asymmetric
  • Membrane potting: Epoxy
  • Membrane material: PAN
  • Housing material: uPVC
  • Fiber arrangement: U-Shape
  • Flow type: Out/In
  • Type of filtration: Dead End
  • Regeneration: Back Flush, Forward Flush, Air Scouring
  • Membrane area: 60 m²/646 ft²
  • Hollow fiber diameter OD/ID: 1.7 mm/0.9 mm
  • Pore size: 0.025 µm
  • Standard preservative: Sodium meta-bisulphite

Mechanical / hydraulic

  • Module diameter: 267 mm/10.5 in
  • Module length: 1737 mm/68.4 in
  • Connectors:
    • Feed port: 2” Victaulic
    • Permeate port: 2” Victaulic
    • Reject port: 2” Victaulic
    • Air inlet port: G1/2”
  • Weight of module at shipping: Approx. 41 kg/90.4 lbs

Operating limits

  • Applicable water flux: ≤ 7.2 m³/h / ≤ 31.7 gpm
  • Capacity feed pump: ≤ 14.4 m³/h / ≤ 63.4 gpm
  • Capacity back flush pump: ≤ 14.4 m³/h / ≤ 63.4 gpm
  • Max. transmembrane pressure: 1 bar / 14.5 psi
  • Max. module pressure: 1.2 bar / 17.4 psi
  • Applicable air scour rate: 3 - 10 Nm³/h / 1.8 - 5.9 scfm
  • Air pressure: < 1.2 bar / < 17.4 psi
  • Temperature range: 5 - 45°C / 41 - 113°F
  • pH range, operation: 2 - 10
  • pH range, cleaning: 1 - 10
  • Note: Operation specifications are depending on feed water quality and operating conditions.

Feed water

  • Max. TSS feed: ≤ 350 mg/L
  • Max. NTU feed: ≤ 300 NTU

Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the official OEM PDF. Contractual data must always match the specific OEM PDF revision used for the project.

Official datasheet (PDF)

Lenntech datasheet mirror

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.