Datasheet summary
Microdyn MD 090 TP 2N
PDF datasheet mirror for Microdyn MD 090 TP 2N (Microdyn-Nadir UF). Verify with OEM before design.
Summary
Product identification
- MICRODYN® - MD 090 TP 2N Filter Module
Mechanical / hydraulic
- Connectors
- Concentrate: Backing Flange DN 80, DIN 2501
- Permeate: Backing Flange DN 32, DIN 2501
Material
- Housing: Polypropylene
- Membrane: Polypropylene
- Sealing: EPDM / Viton
Membrane and Module Data
- Number of tubes: 41
- Inner diameter: 5.5 mm
- Pore size: 0.2 µm
- Membrane area inside: 1.0 m²
- Free flow area: 9.7 cm²
Operating limits
- Membrane Operational Data
- Max. transmembrane pressure inside to outside at 25 °C: 3.0 bar
- Max. transmembrane pressure inside to outside at 60 °C: 2.0 bar
- Max. backpulse pressure above outlet pressure at 25 °C: 2.0 bar
- Max. backpulse pressure above outlet pressure at 40 °C: 1.5 bar
- Processing temperature: 5 - 60 °C
- Feed flow rate at axial velocity of 1 m/s: 3500 l/h
- Housing Operational Data
- Max. pressure: 3 bar
- Max. temperature: 60 °C
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the official PDF. Contractual data must always match the OEM PDF revision used on the project.