Back to Microdyn-Nadir UF
MANN+HUMMEL logo

Datasheet summary

Spira-Cel WY-UP-2440 Series

PDF datasheet mirror for Spira-Cel WY-UP-2440 Series (Microdyn-Nadir UF). Verify with OEM before design.

Summary

Product identification

  • SPIRA-CEL® Modules for Ultrafiltration
  • Series: WY-UP-2440
  • Membrane material: PES
  • Available regular membrane types with Nominal MWCO (kDa):
    • UP005: 5 kDa
    • UP010: 10 kDa
    • UP020: 20 kDa
    • UP150: 150 kDa
  • Note: Not all combinations are available.

Mechanical / hydraulic

  • Module Ø Outside: 62 mm (+0 / -2 mm tolerance)
  • Module Length: 965 mm (+0 / -3 mm tolerance)
  • Permeate tube Ø Outside: 19.05 mm (±0.5 mm tolerance)
  • Permeate tube Length: 1016 mm (+0.1 / -0 mm tolerance)
  • Spacer thickness, diamond type: 44 mil / 1.1 mm
  • Membrane area: 1.8 m²
  • Outer wrap: Industry standard

Operating limits

Recommended operating conditions

  • Prefiltration: ≤ 75 µm
  • Cross flow: 2 m³/h (for water at 25 °C)
  • Permeate pressure: 0 bar

Allowable operating conditions

  • Feed pressure, max.: 10 bar
  • Retentate pressure, min.: 0.7 bar
  • Transmembrane pressure, max.: 10 bar
  • Permeate pressure, max.: 0.35 bar
  • Pressure loss per module, max. (∆pmax): 2 bar
  • Processing temperature: 5 - 50 °C
  • pH range during filtration: 2 - 11
  • pH range during CIP: 2 - 11

Feed water

  • Recommended prefiltration: ≤ 75 µm.

Additional Notes

  • The document mentions "Modules for Pilot Projects" but the associated table is unreadable or incomplete in the extract. See the official PDF for exact tabulated values.
  • Tolerances indicated are composed to the best of MICRODYN-NADIR's knowledge.
  • Warranty is valid if values on this data sheet are followed, along with adherence to rules for installation, cleaning, water, and preservation. Only MICRODYN-NADIR approved cleaning detergent, anti-foam, polymers, other chemicals and filter-aids lubricants can be applied.
  • Modules require a prescribed first cleaning by MICRODYN-NADIR before production.

Disclaimer

This summary is based on extracted text and may miss figures, footnotes, or the latest revisions. Contractual data must always match the official OEM PDF revision used on the project. The manufacturer reserves the right to change specifications without prior notification.

Official datasheet (PDF)

Lenntech datasheet mirror

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.