SpiraSep 960 PVDF

PDF datasheet mirror for SpiraSep 960 PVDF (Microdyn-Nadir UF). Verify with OEM before design.

Summary

Product identification

MICRODYN SpiraSep™ 960-PVDF Ultrafiltration Modules feature a vacuum-driven, submerged, backwashable, spiral-wound membrane design. This unique design, with open feed channels, allows the modules to handle high solids levels in high fouling water and wastewater streams. An advanced aeration process combined with periodic backwashing easily removes particulate matter from the membrane surface. The low net driving pressure of an immersed system minimizes energy costs and membrane fouling.

  • Model: MICRODYN SpiraSep™ 960-PVDF
  • Membrane Chemistry: Polyvinylidene Fluoride (PVDF)
  • Construction: Submerged, Negative Pressure Ultrafiltration Module
  • Pore Size: 0.03 micron

Operating limits

  • Transmembrane Pressure Range: 0.07 – 0.7 bar (1 – 10 psi)
  • Temperature Range¹: 1 – 45°C (34 – 113°F)
  • pH Range¹: 2.0 – 11.0
  • Applicable Air Scour Rate: 5.6 Nm³/hr (3.5 scfm)
  • Cleaning Chlorine Tolerance: 2,000 mg/L

¹ Temperature, pH limits, and cleaning procedures are further detailed in the SpiraSep™ 960 Product Manual.

Feed water

  • Maximum Feed TSS²: 1,000 mg/L
  • Maximum Feed Oil & Grease²: 300 mg/L

² Depending on feed water quality and operating conditions.

Mechanical / hydraulic

  • Feed Channel: 90 mil corrugated
  • Membrane Area: 20.9 m² (225 ft²)
  • Physical Dimensions:
    • Dim. A: 47 mm (1.87 inches)
    • Dim. B: 1,187 mm (46.75 inches)
    • Dim. C: 249 mm (9.80 inches)
  • Element Weight: 23 kg (50 lb)

Important Information

For a more detailed operational sequence, including permeate production, cleaning, and module draining steps, please see SpiraSep 960 Product Manual pages 10-11. Routine cleaning via backwash, chemically enhanced backwash (CEB), and clean-in-place (CIP) is required; refer to SpiraSep 960 Product Manual pages 12-15. Appropriate storage guidelines are detailed in SpiraSep 960 Product Manual pages 18-19.

Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the original OEM PDF datasheet. Contractual data must always match the specific OEM PDF revision used for the project.

Official datasheet (PDF)

Lenntech datasheet mirror

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.