Back to Microdyn-Nadir UF
MANN+HUMMEL logo

Datasheet summary

Spira-Cel GY-UP-4040

PDF datasheet mirror for Spira-Cel GY-UP-4040 (Microdyn-Nadir UF). Verify with OEM before design.

Summary

Product identification

The SPIRA-CEL® GY-UP-4040 Series consists of ultrafiltration modules.

  • Module Types: UP005, UP010, UP020, UP150
  • Membrane Material: PES
  • Nominal MWCO (kDa):
    • UP005: 5
    • UP010: 10
    • UP020: 20
    • UP150: 150
  • Membrane Area: 6.0 m²
  • Spacer Thickness: 44 mil / 1.1 mm
  • Outer Wrap: FRP shell

Mechanical / hydraulic

  • Module Outside Diameter: 101.5 mm (Tolerance: +0 / -2 mm)
  • Module Length: 1016 mm (Tolerance: +1 / -3 mm)
  • Permeate Tube Inside Diameter: 16.0 mm (Tolerance: ± 0.1 mm)
  • Recommended Cross Flow (for water at 25 °C): 6 - 10 m³/h

Operating limits

Recommended operating conditions

  • Prefiltration: ≤ 75 µm
  • Permeate Pressure: 0 bar

Allowable operating conditions

  • Feed Pressure, max.: 10 bar
  • Retentate Pressure, min.: 0.7 bar
  • Transmembrane Pressure, max.: 10 bar
  • Permeate Pressure, max.: 0.35 bar
  • Pressure Loss per Module, max. (∆pmax):
    • 5 - 50 °C: 2 bar
    • 50 - 65 °C: 1.3 bar
    • 65 - 80 °C: 0.5 bar
  • Pressure Loss per Housing, max. at 80 °C: 2 bar
  • Processing Temperature: 5 - 80 °C
  • pH Range during Filtration: 2 - 11
  • pH Range during CIP: 1 - 12

Note: All modules from GY-Series will be delivered with attached ATDs. Not all combinations are available.

Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the original OEM PDF. Contractual data must always match the specific OEM PDF revision used for the project. The manufacturer reserves the right to change specifications without prior notification.