Back to SUEZ Ultrafiltration
SUEZ logo

Datasheet summary

GK series

PDF datasheet mirror for GK series (SUEZ Ultrafiltration). Verify with OEM before design.

Summary

Product Identification

The SUEZ G-Series family of proprietary thin-film ultrafiltration (UF) membrane elements, specifically the GK series, features a molecular weight cutoff (MWCO) of 3,500 Dalton on polyethylene glycol and a smooth, fouling-resistant membrane surface.

GK Elements are designed for applications such as surface water pretreatment, color/TOC reduction, and chemical purification.

Membrane Type: G-Series, Thin-Film Membrane (TFM*) Molecular Weight Cutoff (MWCO): 3,500 Dalton

ModelAverage Permeate Flow gpd (m³/day)¹Spacer mil (mm)Active Area ft² (m²)Outer WrapPart Number
GK2540F30420 (1.6)30 (0.76)28 (2.6)Fiberglass1207129
GK2540F50270 (1.0)50 (1.27)22 (2.0)Fiberglass1207130
GK4040F301,600 (6.0)30 (0.76)85 (7.9)Fiberglass3050009
GK4040F501,000 (3.8)50 (1.27)66 (6.1)Fiberglass3050008
GK8040C504,100 (15.5)50 (1.27)300 (27.9)Cage1207151
GK8040F305,900 (22.3)30 (0.76)364 (33.8)Fiberglass1207152
GK8040F504,000 (15.1)50 (1.27)284 (26.4)Fiberglass1207153

¹Flux specifications are based on fouling-free water at 85 psi operating pressure (586 kPa), 77°F (25°C), and 10% recovery. Individual element flux may vary ± 25%.

Operating Limits

  • Typical Operating Flux: 5-20 GFD (8-34 LMH)
  • Maximum Operating Pressure: 400 psi (2,760 kPa)
  • Maximum Temperature:
    • Continuous Operation: 122°F (50°C)
    • Clean-In-Place (CIP): 122°F (50°C)
  • pH Range:
    • Continuous Operation: 2.0-10.0
    • Clean-In-Place (CIP): 1.0-13.0¹
  • Maximum Pressure Drop:
    • Over an element: 15 psi (103 kPa)
    • Per housing: 60 psi (414 kPa)
  • Chlorine Tolerance: 20-50 ppm days

¹Refer to Cleaning Guidelines Technical Bulletin TB1194.

Mechanical / Hydraulic

Dimensions and Weight:

ModelTypeDimension A inches (cm)Dimension B inches (cm)Dimension C inches (cm)Boxed Weight lbs (kg)
GK2540F**Male40.0 (101.6)0.75 (1.90)2.4 (6.1)4 (1.8)
GK4040F**Male40.0 (101.6)0.75 (1.90)3.9 (9.9)9 (4.1)
GK8040F**Female40.0 (101.6)1.125 (2.86)7.9 (20.1)29 (13.2)
GK8040C**Female40.0 (101.6)1.125 (2.86)7.9 (20.1)29 (13.2)

See the official PDF for Element Dimensions Diagrams (Figure 1: Element Dimensions Diagram – Female; Figure 2: Element Dimensions Diagram – Male).


Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the original OEM PDF datasheet. Contractual data must always match the specific OEM PDF revision used on the project.

Official datasheet (PDF)

Lenntech datasheet mirror

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.