Datasheet summary
MW series
PDF datasheet mirror for MW series (SUEZ Ultrafiltration). Verify with OEM before design.
Summary
Product identification
The MW series consists of industrial oil/water separation Ultrafiltration (UF) elements.
The M-series Ultrafillic membranes are made of polyacrylonitrile (PAN) polymer, characterized by:
- Pore size: 0.01 microns
- Approximate molecular weight cut-off: 20K-50K Dalton
MW–series elements are engineered to be extremely hydrophilic (water attracting) for fouling avoidance. They are used for oil/water separation and suspended solids removal, and as pretreatment for process water before reverse osmosis or nanofiltration.
Mechanical / hydraulic
Element Specifications
- Membrane: M-series, polyacrylonitrile
| Model | Spacer mil (mm) | Active area ft² (m²) | Outer wrap | Part number |
|---|---|---|---|---|
| MW2540F30 | 30 (0.76) | 28 (2.6) | Fiberglass | 1233383 |
| MW4040F50 | 50 (1.27) | 62 (5.8) | Fiberglass | 3050562 |
| MW8040C50 | 50 (1.27) | 264 (24.7) | Cage | 1220654 |
| MW8040F50 | 50 (1.27) | 269 (25.0) | Fiberglass | 1229852 |
Dimensions and Weight
| Model | Type | Dimensions, A inches (cm) | Dimensions, B inches (cm) | Dimensions, C inches (cm) | Weight lbs (kg) |
|---|---|---|---|---|---|
| MW2540F30 | Male | 40.0 (101.6) | 0.75 (1.9) | 2.4 (6.1) | 4 (1.8) |
| MW4040F50 | Male | 40.0 (101.6) | 0.75 (1.9) | 3.9 (9.9) | 9 (4.1) |
| MW8040C50 | Female | 40.0 (101.6) | 1.125 (2.86) | 7.9 (20.1) | 29 (13.2) |
Operating limits
- Typical Operating Flux: 5 - 20 GFD (8 – 34 LMH)
- Maximum Operating Pressure: 100 psi (700 kPa)
- Maximum Temperature:
- For fiberglass elements:
- Continuous operation: 122°F (50°C)
- Clean-In-Place (CIP): 122°F (50°C)
- For cage elements:
- Continuous operation: 176°F (80°C)
- Clean-In-Place (CIP): 122°F (50°C)
- For fiberglass elements:
- pH Range:
- Continuous operation: 3-9
- Clean-In-Place (CIP): 2-11
- Maximum Pressure Drop:
- Over an element: 15 psi (103 kPa)
- Per housing: 60 psi (414 kPa)
- Chlorine Tolerance: 200,000 ppm-hours