Datasheet summary
PT series
PDF datasheet mirror for PT series (SUEZ Ultrafiltration). Verify with OEM before design.
Summary
Product identification
The PT series consists of industrial ultrafiltration elements utilizing a polyethersulfone (PES) membrane with a 5,000-molecular weight cut-off (MWCO).
- Membrane: P-Series, Polyethersulfone
| Model | Spacer mil (mm) | Active area ft² (m²) | Outer wrap | Part number |
|---|---|---|---|---|
| PT8040C50 | 50 (1.27) | 264 (24.5) | Cage | 1240574 |
| PT8040F30 | 30 (0.76) | 340 (31.6) | Fiberglass | 1229772 |
Operating limits
- Typical Operating Flux: 5 – 20 GFD (8 – 34 LMH)
- Maximum Operating Pressure: 200 psi (1,379 kPa)
- Maximum Temperature:
- Continuous Operation: 122°F (50°C)
- Clean-In-Place (CIP): 122°C (50°C)
- pH range:
- Continuous Operation: 2.0-10.0
- Clean-In-Place (CIP): 1.0-11.5
- Maximum Pressure Drop:
- Over an element: 15 psi (103 kPa)
- Per housing: 60 psi (414 kPa)
- Chlorine Tolerance: 5,000 ppm days
Mechanical / hydraulic
| Model | Dimensions, inches (cm) A | Dimensions, inches (cm) B¹ | Dimensions, inches (cm) C² | Boxed Weight lbs (kg) |
|---|---|---|---|---|
| PT8040 | 40.0 (101.6) | 1.125 (2.86) | 7.9 (20.1) | 29 (13.2) |
¹ Internal diameters unless specified OD (outside diameter). ² The element diameter (dimension C) is designed for optimum performance in GE Water & Process Technologies pressure vessels. Other pressure vessel dimensions and tolerances may result in excessive bypass and loss of capacity.