Back to SUEZ Ultrafiltration
SUEZ logo

Datasheet summary

PW series

PDF datasheet mirror for PW series (SUEZ Ultrafiltration). Verify with OEM before design.

Summary

Product identification

  • Product line: PW series
  • Membrane material: P-Series, Polyethersulfone
  • Molecular weight cut off: 20,000
  • Rejection: >96% of Cytochrome-C (13,300 MW protein)
  • Applications: Pretreatment of process water, post treatment of ultrapure water, removal of organics.

Element Specifications

  • PW2540C30: 30 mil (0.76 mm) spacer, 23 ft² (2.1 m²) active area, Cage outer wrap, Part number 1207350
  • PW2540F30: 30 mil (0.76 mm) spacer, 28 ft² (2.6 m²) active area, Fiberglass outer wrap, Part number 1207352
  • PW2540F50: 50 mil (1.27 mm) spacer, 22 ft² (2.0 m²) active area, Fiberglass outer wrap, Part number 1207351
  • PW4025T: 50 mil (1.27 mm) spacer, 50 ft² (4.6 m²) active area, Tape outer wrap, Part number 1207369
  • PW4040C30: 30 mil (0.76 mm) spacer, 82 ft² (7.6 m²) active area, Cage outer wrap, Part number 1207372
  • PW4040C50: 50 mil (1.27 mm) spacer, 63 ft² (5.8 m²) active area, Cage outer wrap, Part number 1207371
  • PW4040F30: 30 mil (0.76 mm) spacer, 79 ft² (7.3 m²) active area, Fiberglass outer wrap, Part number 3050051
  • PW8040C50: 50 mil (1.27 mm) spacer, 264 ft² (24.5 m²) active area, Cage outer wrap, Part number 1207399
  • PW8040F30: 30 mil (0.76 mm) spacer, 365 ft² (33.9 m²) active area, Fiberglass outer wrap, Part number 1207404
  • PW8040F50: 50 mil (1.27 mm) spacer, 269 ft² (25.0 m²) active area, Fiberglass outer wrap, Part number 1207403
  • PW8340C50: 50 mil (1.27 mm) spacer, 276 ft² (25.6 m²) active area, Cage outer wrap, Part number 1223936

Mechanical / hydraulic

Dimensions and Weight

  • PW2540:
    • Dimension A: 40.0 inches (101.6 cm)
    • Dimension B: 0.75 inches (1.9 cm) OD
    • Dimension C: 2.4 inches (6.1 cm)
    • Boxed Weight: 4 lbs. (1.8 kg)
  • PW4025:
    • Dimension A: 25.0 inches (63.5 cm)
    • Dimension B: 0.625 inches (1.59 cm)
    • Dimension C: 3.9 inches (9.9 cm)
    • Boxed Weight: 5 lbs. (2.3 kg)
  • PW4040C:
    • Dimension A: 38.75 inches (98.4 cm)
    • Dimension B: 0.625 inches (16 cm)
    • Dimension C: 3.9 inches (9.8 cm)
    • Boxed Weight: 9 lbs. (4.1 kg)
  • PW4040F:
    • Dimension A: 40.0 inches (101.6 cm)
    • Dimension B: 0.75 inches (1.90 cm) OD
    • Dimension C: 3.9 inches (9.9 cm)
    • Boxed Weight: 8 lbs. (3.5 kg)
  • PW8040:
    • Dimension A: 40.0 inches (101.6 cm)
    • Dimension B: 1.125 inches (2.86 cm)
    • Dimension C: 7.9 inches (20.1 cm)
    • Boxed Weight: 29 lbs. (13.2 kg)
  • PW8340:
    • Dimension A: 40.0 inches (101.6 cm)
    • Dimension B: 1.138 inches (2.89 cm)
    • Dimension C: 8.3 inches (21.1 cm)
    • Boxed Weight: 42 lbs. (19.1 kg)

Notes on dimensions:

  • These elements are bagged dry before shipping.
  • Dimension B refers to internal diameters unless specified OD (outside diameter).
  • Dimension C (element diameter) is designed for optimum performance in SUEZ pressure vessels. Other pressure vessel dimensions and tolerances may result in excessive bypass and loss of capacity.

Operating limits

  • Typical Operating Pressure: 80-135 psig (555 – 931 kPa)
  • Typical Operating Flux: 10-25 GFD (15-40 LMH)
  • Maximum Operating Pressure: 200 psig (1,379 kPa)
  • Clean Water Flux (CWF): 1.3-2.5 gfd/psi (30-60 lmh/bar) at 77°F (25°C)
    • Note: CWF is the rate of water permeability through the membrane after cleaning (CIP) at reproducible temperature and pressure. Monitoring CWF after each cleaning cycle helps determine cleaning effectiveness.
  • Maximum Temperature:
    • Continuous operation: 122°F (50°C)
    • Clean In Place (CIP): 122°F (50°C)
  • pH Range:
    • Continuous operation: 4.0-11.0
    • Clean In Place (CIP): 2.0-11.5
  • Maximum Pressure Drop:
    • Over an element: 12 psig (83 kPa)
    • Per housing: 50 psig (345 kPa)
  • Chlorine Tolerance: 5,000+ ppm-days