ZW1000

PDF datasheet mirror for ZW1000 (SUEZ Ultrafiltration). Verify with OEM before design.

Summary

Product identification

  • Model: ZeeWeed 1000-TT for tertiary treatment
  • Description: Immersed ultrafiltration system, leveraging advanced submerged ultrafiltration technology.
  • Typical Applications: Water reuse applications. Proven to consistently outperform conventional filtration technology while meeting or exceeding regulatory requirements.
  • General Properties:
    • 0.02 µm nominal pore diameter - for optimal removal of particulates, bacteria, and viruses
    • PVDF hollow fiber membrane - provides high mechanical strength and chemical resistance
    • Outside-in filtration - provides uniform flow distribution and high solids tolerance

Operating limits

  • Flow range: 55 – 110 m³/day (10-20 gpm)
  • TMP range: 0-90 kPa (0-13 psi)
  • Max temperature: 40°C (104°F)
  • Operating pH: 5.0-10.0
  • Max air scour flow: 5 dm³/hr (3 dcfm) / stack
  • Cleaning pH range: 2.0-12.0
  • Max chlorine concentration per cleaning: 1,000 mg/L (as Cl₂)

Mechanical / hydraulic

  • Module Dimensions:
    • Height (A): 685 mm (27.0 in)
    • Length (B): 691 mm (27.2 in)
    • Width (C): 107 mm (4.2 in)
  • Nominal membrane surface area: 46.5 m² (500 ft²)
  • Shipping weight¹: 23 kg (50 lb)
  • Typical lifting weight²: 21-27 kg (46-60 lb)
  • Membrane material: PVDF
  • Nominal pore size: 0.02 micron
  • Nominal fiber diameter: OD: 0.8 mm, ID: 0.47 mm
  • Flow path: Outside-in
  • Housing material: ABS, PPE/PPO

Storage and handling

  • Modules may be stored in original factory packaging for up to one year prior to installation.
  • Modules must be stored between 5°C and 35°C (41°F to 95°F).
  • Do not expose the membrane module to direct sunlight (UV light) as the module housing and other plastic components may degrade with extended UV exposure.