Datasheet summary
ZW1500 RMS
PDF datasheet mirror for ZW1500 RMS (SUEZ Ultrafiltration). Verify with OEM before design.
Summary
Product identification
- ZeeWeed* 1500 RMS rackless module system for SUEZ pressurized ultrafiltration (UF).
- Utilizes ZeeWeed membrane technology.
- Module Model: ZeeWeed 1500.
Mechanical / hydraulic
Module Specifications
- Nominal membrane surface area: 55.7 m² (600 ft²)
- Max shipping weight¹: 33.5 kg (72 lb)
- Lifting weight²: 27 – 43 kg (57 - 92 lb)
- Membrane material: PVDF
- Nominal pore size: 0.02 micron
- Nominal fiber diameter: OD: 1.2 mm, ID: 0.66 mm
- Flow path: Outside-In
- Housing material: PVC housing
- Module Diameter: 180 mm (7”)
- Feed & Permeate connection: RMS flange clamp
- Reject connection: 1 ½” (DN40) Victaulic
- System Integration: SUEZ RMS
¹ Packaged, single module ² Varies with solids accumulation, single module
System Configurations
The ZW1500-RMS is available in configurations with 2 or 4 rows of modules.
- Train Width:
- 2 rows of modules: 0.6 m (2 ft)
- 4 rows of modules: 1.2 m (4 ft)
- Connections: 6” Feed, 4” Aeration, 6” Permeate, 6” Reject.
- For specific Train Lengths, Footprints, and Surface Areas based on the number of modules (ranging from 8 to 128 modules), please refer to the official PDF.
Operating limits
Storage and Handling
- Storage temperature: 5°C to 35°C (41°F to 95°F)
- Modules may be stored in original factory packaging for up to 1 year.
- Do not expose to sources of heat, ignition, or direct sunlight (UV light).
Operating Conditions
- Max inlet pressure: 379 kPa (55 psi)
- TMP range: 0 - 276 kPa (0 - 40 psi)
- Max temperature: 40°C (104°F)
- Operating pH: 5.0 - 10.0
- Cleaning pH range: 2.0 - 12.0
- Max chlorine concentration: 1,000 mg/L (as NaOCl)³ ³ Higher concentrations are possible depending on feedwater and pH.
- Seismic rating: Not rated for high seismic zones. A seismic kit is available for special acceleration ratings up to 3.0g upon request.
Product water
- Flow range: 45 - 180 m³/day (8 - 33 gpm)
Feed water
- Air scour flow: 5.1 m³/h (3 dcfm)
- Backwash flow: 1.8 m³/hr (8 gpm)
Disclaimer