Datasheet summary
ZW700B 4100
PDF datasheet mirror for ZW700B 4100 (SUEZ Ultrafiltration). Verify with OEM before design.
Summary
Product identification
- Model: ZW700B-4100/UF10/7B/S/0.9/5.8
- Description: ZeeWeed* Ultrafiltration (UF)
- Fiber Technology: SevenBore* fiber with an inside-out flow orientation. The SevenBore fiber is a robust polyether sulfone (PES) product.
Mechanical / hydraulic
- Housing & Connector Material: PVC
- Element Length: 1142 +/- 3.0 mm (44.96 +/- 0.12 inch)
- Element Length (BSP threaded adaptors): 1200 +/- 3.0 mm (47.24 +/- 0.12 inch)
- Distance Permeate Connector to Feed Connector: 236 +/- 2.0 mm (9.29 +/- 0.08 inch)
- Distance Permeate Connector to Feed Connector (alternate): 265 +/-2.0 mm (10.43 +/- 0.08 inch)
- Distance Permeate Connector to Element Center: 90 +/-2.0 mm (3.54 +/- 0.08 inch)
- Permeate Connection: 1 inch BSP thread
- Feed Connection: 1 inch socket or BSP thread
- Housing OD: 110 mm (4.33 inch)
- Element OD: 125 mm (4.92 inch)
- Endcaps ID: 32 mm (1.26 inch)
- Weight: 4.5 kg (10 lbs.)
- Membrane Material: PES
- Membrane Type: SevenBore
- Diameter Bores ID: 0.9 mm (0.04 inch)
- Diameter Fiber OD: 4.0 mm (0.16 inch)
- Membrane Area: 5.8 m² (62 ft²)
Operating limits
- Maximum Operating Temperature: 40°C (104°F)
- Maximum Operating Pressure: 5 bars (72.5 psi)
- Trans Membrane Pressure (TMP) Operation: <1.0 bar (<14.5 psi)
- TMP Maximum: 2.5 bar (36 psi)
- Backwash/Forward Flush: 250 l/m²h (150 gfd)
- pH Range During Operation: 2 to 11
- Storage Temperature: 5°C to 35°C (45°F to 91°F)
Product water
- Permeate Flow at 100 l/m²h: 580 l/h (3 gpm)
- UF membrane for optimal removal of particulates, bacteria, and viruses.
Cleaning
- Soaking Time During Cleaning: 5 minutes
- Cleaning pH Range: 1.0-13.0
- Disinfecting Chemicals:
- Hypochlorite (NaOCl): 50 to 200 ppm
- Hydrogen Peroxide (H₂O₂): 100 to 200 ppm
General Information
- PES membrane fibers with 7 bores provide high mechanical strength (>10x that of single fibers) and chemical resistance.
- Inside-Out filtration eliminates the air scouring step and additional related equipment.
- Elements are filled with glycerin when new, as part of the fiber manufacturing and preservation process.
- Elements must be stored in a dry and normal ventilated location, away from any sources of heat, ignition, and direct sunlight in the original packing.
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the official OEM PDF. Contractual data must always match the specific OEM PDF revision used on the project.