Engineering diagnostics
Available · Professional review pendingPHY-01 · v1.0.0 · 2026-07-24

Poor coagulation, high turbidity and floc formation

Use this when poor coagulation, high turbidity and floc formation is observed but the cause remains unclear. The diagnostic checks measurement and sampling, operating changes, issue location, and key evidence before suggesting likely causes and the next useful check.

If an alarm, leak, or injury is happening now, follow the site emergency procedure.

Automatic troubleshooting · Selections are not uploaded

Answer from current facts or defer an unknown item. Results update as you answer.

Progress is saved in this browser
  1. 1Data validity
  2. 2Operating changes
  3. 3Issue location
  4. 4Further confirmation

Question progress

0/31

Next question

Phase 1 · Data validity

What is the status of turbidimeter method, range, units, calibration, and bubble/settling interference?

The system asks the question most useful for separating possible causes. Unknown or deferred items are not treated as the opposite conclusion.

Numeric evidence · Local calculation

Calculate directly when operating data is available

Choose a calculation relevant to the issue and enter values in the site units. The tool converts units, checks physical boundaries, and shows the result locally without an AI call or upload.

Values and results stay in this browser

Active chemical dose and solution feed

v1.0.0

Calculates active mass from water flow and target dose, then solution feed from mass fraction and density, with optional back-calculation of actual dose.

Calculated results

Enter the required data for this calculation to see results.

Formula and boundary

Solution strength is mass fraction (% w/w), using density for the current lot/temperature. Do not mix target active dose, product-solution dose, or equivalent bases such as as-Cl₂/as-Al/as-P.

Calculation sources
Baseline-to-current change

Calculates absolute and relative change before interpreting a trend.

Calculated results

Enter the required data for this calculation to see results.

Formula and boundary

Both values must represent the same quantity, point, unit, time basis, and comparable operating condition. Relative percent change is meaningful only on ratio scales with a true zero; pH, Celsius/Fahrenheit temperature, and zero-crossing ORP need a suitable domain model or absolute differences only. Two points do not replace trend analysis or normalization.

Calculation sources
Try an example
I have more test or inspection resultsOptionalAdd laboratory analysis, normalized calculations, or checks completed by trained personnel when available. These fields are optional.
How to use and what to prepare

The system asks one discriminating question at a time and updates the candidate causes on the right. Answer from current facts; choose unknown or defer a question when the evidence is not available.

  1. 1. Confirm the issue · Check whether the symptom is reproducible and whether the measurement or observation is reliable.
  2. 2. Narrow the causes · Continue through operating changes; enter flow, pressure, or quality data for local calculations when available.
  3. 3. Read the live result · Candidate causes, numeric evidence, counter-evidence, conflicts, and next actions update as you answer.

Useful information to have nearby

  • When the issue started, with recent trends or alarm records
  • Relevant instruments, sample points, units, and calibration status
  • Operating changes, cleaning, maintenance, or chemical changes before the issue

Rules and numeric calculations run in this browser. No AI call is made and values are not uploaded.

View rule sources (14)Standards, regulations, OEM material, and peer-reviewed literature used to audit the diagnostic logic. You do not need to read them before starting.