Datasheet summary
Multi Sensor Validation System ( Dual , Triple)
Engineering summary from PDF text extraction for Multi Sensor Validation System ( Dual , Triple). Verify every value with the OEM datasheet.
Summary
Product Identification
This document describes Evoqua's WALLACE & TIERNAN® MULTI SENSOR VALIDATION SYSTEMS, specifically the Triple Validation Monitor and Dual Validation Monitor, which can be used with DEPOLOX® analysers for chlorine residual and turbidity measurements.
Key Benefits
- Improve confidence in water quality
- Minimise chances of out-of-specification water
- Improved security and validity of readings
- High reliability of readings
- Increased confidence in analysers
- Reduced response priority to problems
- Proof of diligence to regulators
Technical Specification
Triple Validation Monitor
Power Supply
- Voltage Range: 100-240V AC (auto sensing), 24Vdc as a special option
- Frequency Range: 50-60Hz
- Power: 30 VA
- Fuse: 2A internal (Non-replaceable)
Digital Input
- 7 x volt free: 24V DC @ 4mA nom. (internal supply)
- Optical Isolation
Digital Output
- 6 x relay: SPST, volt free
- 24V @ 30W dc Max
- 250V @ 200W ac Max
- Watchdog Output: SP NC relay contact
Analogue Input
- 3 x Scaled range 4-20mA
- Resolution: 14 bit Unipolar (5µA)
- Input impedance: 250 Ω
- Isolation: All analogue signals isolated using discreet multi-way signal isolators (see Note 1)
Analogue Output
- 2 x Scaled range 4-20mA
- Resolution: 14 bit Unipolar (5µA)
- Max. load impedance: 600 Ω
- Isolation: All analogue signals isolated using discreet multi-way signal isolators (see Note 1)
Re-transmission Output
- 3 x Scaled range 4-20mA
- Error < 0.1% of end value
- Max. load impedance: 600 Ω
- Isolation: All analogue signals isolated using discreet multi-way signal isolators (see Note 1)
Enclosure
- Environmental: IP65 (door closed)
- Operating temperature: 0 - 40°C (90% non-condensing)
- Storage temperature: -20 to +70°C
- Mounting: Wall mounted painted steel enclosure, Landscape
Physical
- Dimensions: 300 x 400 x 150mm (h x w x d)
- Weight: 8kg
Dual Validation Monitor
Power Supply
- Voltage Range: 100-250V AC (auto sensing), 24Vdc as a special option
- Frequency Range: 50-60Hz
- Power: 30 VA
- Fuse: 2A internal (Non-replaceable)
Digital Input
- 2 x volt free: 24V DC @ 4mA nom. (internal supply)
- Optical Isolation
Digital Output
- 4 x relay: SPST, volt free
- 24V @ 30W dc Max
- 250V @ 200W ac Max
- Watchdog Output: SP NC relay contact
Analogue Input
- 2 x Scaled range 4-20mA
- Resolution: 14 bit Unipolar (5µA)
- Input impedance: 250 Ω
- No Isolation
Analogue Output
- 1 x Scaled range 4-20mA
- Resolution: 14 bit Unipolar (5µA)
- Max. load impedance: 600 Ω
- No Isolation
Enclosure
- Environmental: IP65 (door closed)
- Operating temperature: 0 - 40°C (90% non-condensing)
- Storage temperature: -20 to +70°C
- Mounting: Wall mounted plastic enclosure, Landscape
Physical
- Dimensions: 260 x 350 x 250mm (h x w x d)
- Weight: 5kg
Note 1 All analogue signals to and from the Validation Monitor are isolated using discreet multi-way signal isolators.
Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.