Datasheet summary
BLU-Sentinel Pro Pool & Spa Chemistry Controller
Engineering summary from PDF text extraction for BLU-Sentinel Pro Pool & Spa Chemistry Controller. Verify every value with the OEM datasheet.
Summary
Product identification
- Product Name: BLU-Sentinel Pro Pool & Spa Chemistry Controller
- Product Line: Wallace & Tiernan Analyzers - Controllers
Design and Function
The Blu-Sentinel Pro is a pool and spa water controller designed to optimize disinfection for safe bather experience. It measures pH, ORP, and free chlorine using Strantrol® sensing technology and an amperometric bare electrode. A hydro-mechanical cleaning process with circulating grit keeps the free chlorine electrode clean from lotions and oils.
The system comprises a flow cell module and an electronic module. The measurement module houses sensors, processes data, and transmits it to the electronics via a digital CAN bus cable. Optional sensor status indication uses red, yellow, and white LEDs.
Flow Cell Module
- Controlled Sample Water Flow: 33 l/h
- Flow Control Valve Inlet Pressure Range: 0.2 – 3.0 bar (3 – 43 psig)
- Maximum Back Pressure: Up to 1.5 bar (22 psig) at valve outlet
- Maximum Sample Water Temperature: 50 °C
- Multi-sensor:
- Monitors sample water flow at 18 l/h ± 3 l/h (hysteresis: 2 l/h)
- Measures sample water temperature via Pt 1000 sensor
- Sample Water Connections: PVC hose 6 x 3 mm or PE hose 6 x 1 mm
- Dimensions: 253 x 375 x 163 mm (8.5 x 15 x 6 inches)
- Weight: Approx. 2 kg (5.5 lbs)
- Voltage Supply: 24 V DC from the electronic module via CAN connection
Electronic Module
- Touchpanel: 7-inch graphic display with backlight, resistive touch screen, 800 x 480 Pixel resolution.
- Supported Sensors: CAN-Sensor interface for flow module, digital sensors (total/combined chlorine, conductivity).
- Analog Inputs: 1 x feed rate display.
- Digital Inputs: 3 x freely selectable.
- Output (relay) contacts: 8 freely assignable, expandable to 12. Max. 6A/250 V AC, 0.2 A/220 V DC.
- Analog Outputs (optional): 4 x 0/4 – 20 mA, galvanically isolated.
- Power Supply: 100 – 240 V ± 10% or 24 V DC, 50/60 Hz.
- Ambient Temperature: 0 – 50 °C (32 – 122 °F).
- Enclosure: IP 66.
- Dimensions: 320 x 311 x 153 mm (12.5” x 12” x 12.9”).
- Weight: Approx. 4.5 kg (10 lbs).
Sensors
- Free Chlorine:
- Potentiostatic 3-electrode amperometric design.
- Measuring Range: 0 to max 20 mg/l.
- Resolution: Up to 10 mg/l: 0.01 mg/l; up to 20 mg/l: 0.1 mg/l.
- Temperature Compensation: 0 – 50 °C.
- Plug Connection: IP 67.
- Total Chlorine (optional):
- Potentiostatic 3-electrode amperometric membrane design.
- Measuring Range: 0 to max 20 mg/l.
- Resolution: Up to 10 mg/l: 0.01 mg/l; up to 20 mg/l: 0.1 mg/l.
- Temperature Compensation: 0 – 45 °C.
- Plug Connection: IP 67.
- Applicable for salt water pools with up to 4% salt concentration.
- Combined Chlorine (optional):
- Calculated as the difference between total and free chlorine.
- Displayed Range: 0 to max 20 mg/l.
- Resolution: Up to 10 mg/l: 0.01 mg/l; up to 20 mg/l: 0.1 mg/l.
- pH Value:
- Measuring Range: 0 to 14 pH.
- Resolution: 0.01 pH.
- Temperature Compensation: 0 – 50 °C.
- Plug Connection: IP 67.
- ORP:
- Measuring Range: 0 to 400 mV or 500 to 1000 mV.
- Resolution: 1 mV.
- Plug Connection: IP 67.
- Conductivity (optional):
- Measuring Ranges: 10, 20, 50, 100 mS/cm.
- Resolution: 0.1 mS/cm.
- Switchable to NaCl display in mg/l and %.
- Temperature Compensation: 0 – 50 °C.
- Temperature:
- Measured by integral Pt 1000 sensor.
- Measuring Range: 0 to 50 °C.
- Resolution: 0.1 °C.
Operating Modes and Features
- CEDOX Control Mode: Free chlorine control within ORP brackets, aiming to use as little chlorine as possible but as much as necessary.
- DIN Contact: Digital output to circulation pump to reduce flow when parameters are within specified limits.
- Economic Mode: Optimized control parameters for reduced recirculation flow (e.g., lower chlorine setpoint).
- Super Chlorination: Automated process.
- Flocculation Control: Regulates flocculant dosing pump and adjusts to ECO operating mode.
- Combined/Total Chlorine Measurement: Optional sensor with control output.
- Conductivity Measurement: Optional, for maintaining constant salinity in salt water pools.
- Relay Outputs: 8 standard programmable relays, expandable to 12.
- Trend Diagrams: Available for all measured parameters.
- Data Management: External USB for data download, configuration upload/download, and firmware updates.
- Remote Access: Via Smartphone, tablet, or PC when connected to a local area network.
- Integral Safety Functions:
- Safety shutdown for circulating pump failure, supply-tank-empty alarm, or sample water failure.
- Feed time monitoring and delay.
- Controller stop on sensor failure.
- Additional Integrated Controls:
- Start-stop control of UV or activated carbon slurry feed systems.
- Controlling salt concentration in salt water pools (with optional conductivity sensor).
- Adaption Mode: For initial commissioning to optimize chemical feed.
- Chemical Feed Rate Indication: Real-time rates displayed graphically; option to stop feed if thresholds are surpassed.
Communication Interfaces
- Local Area Network: Enables remote panel replication on smartphone, tablet, or PC.
- Field Bus Modules (optional): Supports Modbus TCP, Profinet I/O, or Profibus DP protocols.
- 0/4 – 20 mA Output (optional): For measurement data transfer of up to four variables.
- USB Connection: For data and configuration management, firmware updates.
- Process Monitoring System (optional): For monitoring multiple pools.