Summary

Product identification

  • Corode filter unit models CF01CM and CF02CM.
  • Units include a Corode magnetic drive pump CPMD-01.

Operating limits

  • Filter housing in PP: maximum temperature 80°C
  • Filter housing in PVDF: maximum temperature 100°C
  • Maximum flow (Q max): 1.8 m³/h
  • Minimum flow (Q min): 0.2 m³/h

Electrical

  • Motor: 0.09 kW, 230 V, 0.48 Amp, 1 Ph, 50 Hz, IP55
  • Other voltage options and 60 Hz available on request.

Mechanical / hydraulic

  • Materials:
    • Filter housing: PP or PVDF
    • Pump head: PP or PVDF
    • Outside metal: SS316
  • Connections:
    • Suction pump connection: Ø19mm
    • Outlet filter unit connection: Ø19mm
  • Filter Media:
    • Type: Cartridge
    • Filter housing sizes: 10” or 20”
  • Model-specific dimensions and filter area:
    • CF01CM PP or PVDF:
      • Length (L): 30 cm
      • Width (W): 25 cm
      • Height (H): 60 cm
      • Filter media: 1x10” Cartridge
      • Filter area: 0.33 m²
    • CF02CM PP or PVDF:
      • Length (L): 30 cm
      • Width (W): 25 cm
      • Height (H): 85 cm
      • Filter media: 1x20” Cartridge
      • Filter area: 0.66 m²
  • Standard features:
    • Air release and drain valve
    • Equipped with on/off switch
  • Optional features:
    • Dry run protector
    • Hand priming pump

Performance Graph

A graph illustrates the relationship between discharge (in meters) and capacity (in m³/h). See the official PDF for exact tabulated values.