Back to Corode Pumps
Corode logo

Datasheet summary

CJF30 jumbo

PDF datasheet mirror for CJF30 jumbo (Corode Pumps). Verify with OEM before design.

Summary

Product identification

This document describes Corode filter units, specifically the CFJ30..M Jumbo series, designed for 30,000 l/h capacity with a PP filter housing. The unit includes a Corode magnetic drive pump, model CPMD-30.

Available models and their filter media:

  • CFJ30CM PP: Cartridge
  • CFJ30PM PP: Paper
  • CFJ30C20M PP: Cartridge
  • CFJ30P20M PP: Paper

Operating limits

  • Maximum Capacity (Q max): 30 m³/h
  • Minimum Capacity (Q min): 4 m³/h
  • Filter housing maximum temperature: 80°C
  • A performance curve for "water 20°C" is provided, showing Discharge in m versus Capacity in m³/h. The curve indicates discharge up to 30 m and capacity up to 40 m³/h.

Electrical

  • Motor: 2.2 kW, 400 V, 7.4/4.3 Amp, 3 Ph, 50 Hz, IP55
  • Other voltage options and 60 Hz are available on request.

Mechanical / Hydraulic

  • Filter Housing Material: PP
  • Pump Head Material: PP
  • Outside Metal: SS316
  • Filter Housing Height Options: 10”, 20”

Dimensions (L x W x H)

  • CFJ30CM PP: 70 cm x 70 cm x 120 cm
  • CFJ30PM PP: 70 cm x 70 cm x 120 cm
  • CFJ30C20M PP: 70 cm x 70 cm x 150 cm
  • CFJ30P20M PP: 70 cm x 70 cm x 150 cm

Connections

  • Suction pump: Ø50mm
  • Outlet filter unit: Ø50mm

Filter Media and Area

  • CFJ30CM PP: Cartridge 36x10”, Filter area 11.88 m²
  • CFJ30PM PP: Paper 35xØ456, Filter area 6.00 m²
  • CFJ30C20M PP: Cartridge 36x20”, Filter area 23.76 m²
  • CFJ30P20M PP: Paper 62xØ456, Filter area 12.00 m²

Standard Inclusions

  • Thermal overload switch
  • Air release/ drain valve
  • Pressure gauge

Optional Features

  • Dry run protector
  • Hand priming pump
  • Transport wheels
  • Precoat tank PP 10”xØ500 (50 liter)
  • Precoat tank PP 20”xØ500 (100 liter)

Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the official OEM PDF datasheet. Contractual data must always match the specific OEM PDF revision used for the project.

Official datasheet (PDF)