EBARA CVM series multistage centrifugal pumps are designed for 50 Hz operation.
Operating limits
- Liquid Temperature: min. +5 °C, max. +40 °C
- Maximum Working Pressure: 1.1 MPa
- Minimum Flow Rate: Pumps should not be used at a flow rate below 10% of the best efficiency point to avoid the risk of overheating.
Feed water
- Type of Liquid: Clean water
- Temperature: min. +5 °C, max. +40 °C
- Kinematic Viscosity (for performance curves): ν = 1 mm²/s (1 cSt) at 20 °C
Electrical
- Motor Type: Electric asynchronous - TEFC
- Number of Poles: 2
- Rotation Speed:
- Motor: ≈ 2850 min⁻¹
- Performance Curves: ≈ 2800 min⁻¹
- Insulation Class: F
- Protection Degree (CEI EN 60034-5): IP 44
- Frequency: 50 Hz
- Voltage:
- Single Phase: 230 ±10% V
- Three Phase: 230/400 ±10% V
- Power Rating:
- Single Phase: 0.3 ÷ 1.7 kW (0.4 ÷ 2.3 HP)
- Three Phase: 0.3 ÷ 1.85 kW (0.4 ÷ 2.5 HP)
- Capacitor: Built in (Single Phase models), Not applicable (Three Phase models)
- Overload Protection: Built in (Single Phase models), Provided by the user (Three Phase models)
- Casing Material: Aluminium
- Cable Entry Dimensions: PG 11 – PG 13.5 - M16x1.5 – M20x1.5
- Efficiency Level (Reg. 640/2009):
- From 0.3 kW up to 0.6 kW: Not specified
- IE2: From 0.75 kW up to 1.85 kW
- IE3: From 0.75 kW up to 1.85 kW
- Detailed Motor Data: For specific efficiency percentages, full load current, locked rotor current, and capacitor values per model, see the official PDF for exact tabulated values.
Mechanical / hydraulic
- Pump Type: Multistage Centrifugal
- Construction:
- Impeller: Closed centrifugal, PPE+PS Glass fibre reinforced (diameter = 102 mm for CVM A/B models listed)
- Shaft Seal Type: Mechanical seal
- Bearing: Sealed ball bearing
- Pipe Connection:
- Suction: G 1”¼ UNI ISO 228
- Discharge: G 1”¼ UNI ISO 228
- Materials:
- Casing (Suction/Delivery): Cast iron EN-GJL-200-EN 1561
- External Pump Casing: AISI 304 (EN 1.4301)
- Shaft: AISI 416 (EN 1.4005)
- Shaft Seal: Ceramic/Carbon/NBR
- Stages: PPE+PS Glass fibre reinforced /PTFE
- Diffuser: PPE+PS Glass fibre reinforced
- Bracket: Cast iron
- Motor Casing: Aluminium
- Fan: PA
- Fan Cover: Galvanized Fe P04
- Terminal Box Cover: Aluminium (for three phase models)
- Priming Plug: OT 58 UNI 5705
- Drain Plug: OT 58 UNI 5705
- Counter Flange: Cast iron EN-GJL-200-EN 1561
- Counter Flange Gasket: NBR
- Tie Rod: Galvanized Fe P04
- Capacitor Box / Cover: ABS class V-0 (for single phase models)
- Mechanical Seal Components:
- Up to 0.6 kW models: Rotary seal ring (Carbon graphite), Stationary seal ring (Ceramic), Gasket (NBR), Bellows (NBR), Self driving spring (AISI 304), Frame (AISI 304), Retainer ring (AISI 304).
- 0.75 kW and above models: Rotary seal ring (Ceramic), Stationary seal ring (Carbon graphite), O Ring (NBR), Self driving spring (AISI 316), Frame (AISI 304).
- Applicable Standard of Test: ISO 9906:2012 - Grade 3B
- Performance Range and Selection Chart: For detailed capacity (Q) and total manometric head (H) values for each pump model, see the official PDF for exact tabulated values.
- Dimensions and Weight: For specific dimensions and weights per pump model, see the official PDF for exact tabulated values.
- Bearings: For specific ball bearing types (e.g., 6304 2RSH C3, 6203-ZZ C3) for pump side and fan side, per pump type and phase, see the official PDF for exact tabulated values.
Noise Data
- Sound Pressure Level (LpA): Ranges from 53 dB(A) to 67 dB(A) depending on the model.
- Tolerance: ± 2.5 dB.
- Measurement: Mean value of several measures at 1m distance around the pump.