Back to Ebara Pumps
Ebara logo

Datasheet summary

40DSF / 50DS / 65DS / 80DS / 100DS / 50DV / 65DV / 65DL / 80DL / 100DL / 150DL / 200DL / 250DL / 300DL / 80DML / 100DML / 150DML / 50DMLF / 80DMLV / 100DMLV

PDF datasheet mirror for 40DSF / 50DS / 65DS / 80DS / 100DS / 50DV / 65DV / 65DL / 80DL / 100DL / 150DL / 200DL / 250DL / 300DL / 80DML / 100DML / 150DML / 50DMLF / 80DMLV / 100DMLV (Ebara Pumps). Verify with OEM before design.

Summary

Ebara D Series submersible pumps are designed for a variety of applications, including dirty water, water containing foreign matter, and sewage. This summary outlines key specifications for models operating at 50 Hz.

Product identification

The Ebara D Series includes the following submersible pump types:

  • DS: Sump Pump
  • DSF: Sump Pump
  • DVS: Semi-Vortex Pump
  • DL: Sewage Pump
  • DL W/C: Sewage Pump (with cutting action)
  • DML: Sewage Pump
  • DMLF: Sewage Pump
  • DMLV: Sewage Pump
  • DMLVF: Sewage Pump
  • DRS: Sewage Pump (Grinder)
  • DRD: Dirty Waters/Waste Water Pump (with channels)

Operating limits

  • Max Temperature: 40°C (or <40°C for some models)
  • Max Submergence: Varies by model and power, typically 3 m, 7 m, or 20 m.
  • Min Submergence: Refer to low water level (L.W.L.) and usage restrictions in the official PDF dimensions section.

Feed water

  • Type of liquid:
    • DS, DSF: Dirty water
    • DVS: Water containing foreign matter
    • DL, DL W/C, DML, DMLV, DMLVF, DRS: Sewage
    • DMLF: Non corrosive dirty waters also with solid bodies in suspension
    • DRD: Dirty Waters
  • Max solids size: Varies significantly by pump type and model.
    • DS: 5 mm (50DS) to 8 mm (100DS)
    • DSF: 6 mm to 7 mm (40DSF56T2AG)
    • DVS: 21 mm (50DVS) to 41 mm (65DVS & 80DVS 2.2 - 3.7 kW)
    • DL: 35 mm (65DL) to 90 mm (300DL up to 22kW)
    • DL W/C: 35 mm (65DLW/C) to 60 mm (100DLB W/C)
    • DML: 76 mm
    • DMLF: 30 mm (50DMLF) to 40 mm (65DMLF)
    • DMLV: 80 mm (80DMLV) to 100 mm (100DMLV)
    • DMLVF: 30 mm (40DMLVF) to 80 mm (100DMLVF55.2T6BG**), with some models handling 40x50 mm.
    • DRS: 6 mm (many 40DRS models) to 10 mm (many 65DRS models)
    • DRD: Varies widely, e.g., 30 mm (65-80DRD) to 112 mm (350DRD), with some models handling 50x140 mm.
  • Max fibers length: Varies significantly by pump type and model.
    • DS: 50 mm
    • DVS: 100 mm (50DVS) to 245 mm (65DVS & 80DVS 2.2 - 3.7 kW)
    • DL: 195 mm (65DL) to 600 mm (300DL up to 22kW)
    • DL W/C: 195 mm (65DLW/C) to 300 mm (100DLW/C)
    • DML: 500 mm
    • DMLV: 400 mm (80DMLV) to 500 mm (100DMLV)

Electrical

  • Frequency: 50 ±1% or 50 -5/+3 %
  • Protection degree: IP 68 (all models)
  • Insulation Class: F or H (varies by model)
  • Cable material: H07RN-F or Neoprene H07RN/F
  • Cable length: 6 m (up to 1.5 kW for DS, DVS) or 10 m (most other models)
  • Cable size: Varies significantly by model and power rating. See the official PDF for exact tabulated values.
  • Bearings: Permanently lubricated sealed ball bearings, Life lubricated maintenance free, Overdimensioned life lubricated maintenance free, or Overdimensioned double ball bearing with greasers (varies by model and pole count).

DS (Sump Pump)

  • Type: Three Phase air filled dry submersible
  • No. of Poles: 2
  • Rotation speed: ~ 2850 min⁻¹
  • Power Rating: 1.5 ÷ 7.5 kW
  • Voltage: 380-415 ±10%
  • Starting: DOL
  • Over load protection: Built in

DSF (Sump Pump)

  • Type: Dry motor, cooled by surrounding liquid
  • No. of Poles: 2
  • Rotation speed: 2850 min⁻¹
  • Power Rating: Single Phase: 1.5 ÷ 1.9 kW; Three Phase: 6.0 kW
  • Voltage: Single Phase: 230 ±10%; Three Phase: 400/690 ±10%
  • Starting: Single Phase: DOL; Three Phase: DOL - Y/Δ
  • Over load protection: Yes
  • Humidity probe: Yes (Three Phase only)
  • Floating switch: Yes (Single Phase only)

DVS (Semi-Vortex Pump)

  • Type: Three Phase air filled dry submersible
  • No. of Poles: 2
  • Rotation speed: ~ 2850 min⁻¹
  • Power Rating: 1.5 ÷ 3.7 kW
  • Voltage: 380-415 ±10%
  • Starting: DOL
  • Over load protection: Built in

DL (Sewage Pump)

  • Type: Three Phase air filled dry submersible
  • No. of Poles: 4
  • Rotation speed: ~ 1450 min⁻¹
  • Power Rating: 1.5 ÷ 45 kW
  • Voltage: 380-415 ±10% (1.5÷7.5 kW), 400-415 ±10% (Δ connection 11÷22 kW), 380-415 ±10% (Δ connection 30÷45 kW)
  • Starting: DOL up to 7.5 kW, Y/Δ from 11 kW up to 45 kW
  • Over load protection: Built in

DL W/C (Sewage Pump)

  • Type: Three Phase air filled dry submersible
  • No. of Poles: 4
  • Rotation speed: ~ 1450 min⁻¹
  • Power Rating: 1.5 ÷ 7.5 kW
  • Voltage: 380-415 ±10%
  • Starting: DOL (Direct on line)
  • Over load protection: Built in

DML (Sewage Pump)

  • Type: Three Phase air filled dry submersible
  • No. of Poles: 4
  • Rotation speed: ~ 1450 min⁻¹
  • Power Rating: 2.2 ÷ 22 kW
  • Voltage: 380-415 -10+6% (2.2 kW), 380-415 ±10% (3.7÷22 kW)
  • Starting: DOL 2.2 kW, Y/Δ from 3.7 kW up to 22 kW
  • Over load protection: Built in motor protector 2.2 kW, Built in heat probe from 3.7 kW up to 22 kW

DMLF (Sewage Pump)

  • Type: Single Phase, Dry motor, cooled by surrounding liquid
  • No. of Poles: 2
  • Rotation speed: 2850 min⁻¹
  • Power Rating: 1.4 ÷ 1.9 kW
  • Voltage: 230 ±10%
  • Starting: DOL
  • Over load protection: Yes
  • Floating switch: Up to 1.9 kW

DMLV (Sewage Pump)

  • Type: Three Phase air filled dry submersible
  • No. of Poles: 4
  • Rotation speed: ~ 1450 min⁻¹
  • Power Rating: 2.2 ÷ 22 kW
  • Voltage: 380-415 -10+6% (2.2 kW), 380-415 ±10% (3.7÷22 kW)
  • Starting: DOL 2.2 kW, Y/Δ from 3.7 kW up to 22 kW
  • Over load protection: Built in motor protector 2.2 kW, Built in heat probe from 3.7 kW up to 22 kW

DMLVF (Sewage Pump)

  • Type: Dry motor, cooled by surrounding liquid (some models available with cooling jacket)
  • No. of Poles: 2, 4, or 6 (varies by model)
  • Rotation speed: 2850 min⁻¹ (2 poles), 1450 min⁻¹ (4 poles), 950 min⁻¹ (6 poles)
  • Power Rating: 0.5 ÷ 18.2 kW (general range); specific models at 4.9 kW (4 poles) and 5.2 kW (6 poles)
  • Voltage: Single Phase: 230 ±10%; Three Phase: 400/690 ±10%
  • Starting: Single Phase: DOL; Three Phase: DOL - Y/Δ
  • Over load protection: Yes
  • Humidity probe: Yes (Three Phase only)
  • Floating switch: Up to 1.9 kW (Single Phase only)

DRS (Sewage Pump)

  • Type: Dry motor, cooled by surrounding liquid
  • No. of Poles: 2
  • Rotation speed: 2850 min⁻¹
  • Power Rating: 1.1 ÷ 5.0 kW (40DRS); 7.5 ÷ 25.1 kW (65DRS)
  • Voltage: Single Phase: 230 ±10%; Three Phase: 400/690 ±10%
  • Starting: Single Phase: DOL; Three Phase: DOL - Y/Δ
  • Over load protection: Yes (Single Phase), Varies (Three Phase, some models No, some Yes)
  • Humidity probe: No (Single Phase), Varies (Three Phase, some models No, some Yes)
  • Floating switch: Up to 1.9 kW (Single Phase only)

DRD (Dirty Waters/Waste Water Pump)

  • Type: Three Phase, Dry motor, cooled by surrounding liquid (available also with cooling jacket)
  • No. of Poles: 2, 4, 6, or 8 (varies by model)
  • Rotation speed: 2850 min⁻¹, 1450 min⁻¹, 950 min⁻¹, or 750 min⁻¹ (depending on pole count)
  • Power Rating: Varies widely by model, e.g., 3.1 ÷ 7.5 kW (65-80DRD), 2.7 ÷ 20 kW (100DRD), 6 ÷ 80 kW (150DRD), 6 ÷ 48 kW (200DRD), 12.4 ÷ 85 kW (250DRD), 21.8 ÷ 65 kW (300DRD), 40 ÷ 45 kW (350DRD).
  • Voltage: 400 ±10% or 400/690 ±10% (varies by model)
  • Starting: DOL - Y/Δ
  • Over load protection: Yes (most models), No (some specific models)
  • Humidity probe: Yes (most models), No (some specific models)

Mechanical / hydraulic

  • Applicable standard of test: ISO 9906 Annex A (all models)
  • Impeller type:
    • DS: Semi-open (with strainer)
    • DSF: Drainage
    • DVS: Semi – Vortex
    • DL: Non clog, semi-open
    • DL W/C: Non clog, semi-open with cutting action
    • DML, DMLF: Non clog, single channel
    • DMLV, DMLVF: Vortex
    • DRS: Grinder
    • DRD: With channels
  • Shaft seal type:
    • DS, DVS, DML, DMLV, DMLVF: Oil lubricated, single spring double mechanical seal
    • DSF, DMLF, DRS, DRD: Oil lubricated, single spring single mechanical seal + Lip Seal
    • DL, DL W/C: Oil lubricated, single (up to 3.7 kW) or tandem (5.5 kW and above) springs double mechanical seal
  • Suction connection: Strainer (DS), Open (DVS, DL, DL W/C, DML, DMLV), or varies by model number for DSF, DMLF, DMLVF, DRS, DRD.
  • Discharge connection: Varies significantly by pump type and model.
    • DS: G1½ UNI ISO 228 (50DS 1.5 kW), DN 50, 65, 80, 100 PN 10 (EN 1092-2)
    • DSF: DN40 (EN 1092-2)
    • DVS: G1½ UNI ISO 228 (50DVS 1.5 kW), DN 50, 65, 80 PN 10 (EN 1092-2)
    • DL: Flange DN 65, 80, 100, 150, 200, 250, 300 PN 10 (EN 1092-2)
    • DL W/C: Flange DN 65, 80, 100 PN 10 (EN 1092-2)
    • DML: Flange DN 80, 100, 150 PN 10 (EN 1092-2)
    • DMLF: 50 mm (50DMLF), DN65 (EN 1092-2) (65DMLF)
    • DMLV: Flange DN 80, 100 PN 10 (EN 1092-2)
    • DMLVF: 1”¼ (40DMLVF), 50 mm (50DMLVF), 65 mm (65DMLVF), DN80 (EN 1092-2) (80DMLVF), DN100 (EN 1092-2) (100DMLVF)
    • DRS: 40 mm (40DRS), DN65 (EN 1092-2) (65DRS)
    • DRD: Varies by model, e.g., DN65 (EN 1092-2) (65DRD) to DN350 (EN 1092-2) (350DRD).
  • Materials:
    • Casing: Cast iron or Cast iron EN-GJL-250
    • Impeller: Cast iron, Cast-iron GS400, Cast-iron EN-GJL-250+Ni, Cast-iron EN-GJS-400, or Cast-iron EN-GJS-250 (varies by model)
    • Suction Cover: Stainless Steel (DS 1.5 kW), Cast iron, or Cast iron EN-GJL-250
    • Shaft: AISI 403 or Stainless Steel AISI 420B/431
    • Motor frame: Cast iron or Cast iron EN-GJL-250
    • Fasteners: AISI 304 or A2 class - AISI 304
    • Mechanical seal (Impeller side): SiC/SiC/NBR, SiC, or NBR
    • Mechanical seal (Motor side): Carbon/Ceramic/NBR, NBR, SiC, or Ceramic/Graphite
    • O-rings and lip seal: Nitrile (for models with lip seal)
    • Lubricant: Turbine Oil VG32 (SAE 10W/20W) or AGIP ITE 360 (varies by model)
  • Standard Accessories:
    • DS: Screwed flange oval type (1.5 kW), Discharge elbow (2.2÷7.5 kW)
    • DVS: Screwed companion oval flange (50 DVS), Discharge elbow (65DVS & 80DVS)
    • DL, DL W/C, DML, DMLV: Discharge elbow
    • DSF, DMLF, DMLVF, DRS, DRD: Screwed flange square type, Discharge threaded elbow
    • DRS (Single Phase only): Control Panel with capacitor and disjunctor
  • Optional Accessories: Quick Discharge Connector (QDC) of various types (LS, LM, LL, PA).

Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the complete OEM PDF datasheet. For contractual data and full specifications, always refer to the official OEM PDF revision used on the project.

Official datasheet (PDF)

Lenntech datasheet mirror

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.