Datasheet summary
DWC / DWO
PDF datasheet mirror for DWC / DWO (Ebara Pumps). Verify with OEM before design.
Summary
Product Identification
EBARA DWC Series Centrifugal Pumps (50Hz) are available in various models and connection types.
- Models: DWC 300/1.1, DWC 300/1.5, DWC 500/1.5, DWC 500/2.2, DWC 500/3.0
- Connection Types:
- DWC-V: Victaulic connection
- DWC-N: Threaded connection
Operating Limits
- Liquid Temperature:
- Minimum: -15 °C
- Maximum: +90 °C (Standard and Special mechanical seal)
- Maximum: +110 °C (Optional mechanical seal)
- Maximum Working Pressure: 0.8 MPa
Feed Water
- Type of Liquid: Moderate aggressive fluids, glycol solutions, liquids suitable for industrial washing equipment. Not suitable for drinking water. For other industrial fluids, contact Technical Customer Service.
- Impurities: Liquids containing impurities.
- Test Conditions for Curves: Measurements were carried out with clean water at 20 °C of temperature and with a kinematic viscosity of 1 mm²/s (1 cSt).
Electrical
- Motor Type: Electric - TEFC, Three Phase
- Efficiency Level (Reg. 640/2009):
- IE2 from 1.1 kW up to 3.0 kW
- IE3 from 1.1 kW up to 3.0 kW
- Number of Poles: 2
- Rotation Speed: ≈2800 min⁻¹
- Insulation Class: F
- Protection Degree (CEI EN 60034-5): IP 55
- Power Rating: 1.1 ÷ 3.0 kW (1.5 ÷ 4.0 HP)
- Frequency: 50 Hz
- Voltage: 230/400 V ±10%
- Overload Protection: User provide
- Cable Entry Dimensions: PG11 - PG13.5 – M20x1.5
- Motor Data: Detailed motor data, including input power, efficiency at various loads (50%, 75%, 100%), full load current, and locked rotor current for 230 V and 400 V, are available in the official PDF for each pump type and IE2/IE3 motor configuration. See the official PDF for exact tabulated values.
Mechanical / Hydraulic
- Pump Type: Centrifugal, closed impeller.
- Shaft Seal Type: Mechanical seal.
- Bearing Type: Sealed ball bearing.
- Pipe Connection:
- Suction: Victaulic connection Ø 2” (60.3 mm) for DWC-V models; G 2” for DWC-N models.
- Discharge: Victaulic connection Ø 2” (60.3 mm) for DWC-V models; G 2” for DWC-N models.
- Materials of Construction:
- Casing: EN 1.4301 (AISI 304)
- Impeller: EN 1.4301 (AISI 304)
- Casing Cover: EN 1.4301 (AISI 304)
- Shaft Seal (Standard): Ceramic/Carbon/EPDM
- Shaft: EN 1.4301 (AISI 304) (Wet extension)
- Bracket: Aluminium
- Motor Casing Material: Aluminium
- Base Material/Motor Support: Aluminium
- Applicable Standard of Test: ISO 9906:2012 Grade 3B.
- Impeller Diameters:
- DWC 300/1.1: 133 mm
- DWC 300/1.5: 148 mm
- DWC 500/1.5: 125 mm
- DWC 500/2.2: 140 mm
- DWC 500/3.0: 148 mm
- Performance Range: Performance charts detailing total head (H) in meters versus capacity (Q) in l/min and m³/h are available in the official PDF. The recommended working range is indicated by continuous curves, while dotted curves are a guide. Pumps should not be used at a flow rate below 10% of the best efficiency point to avoid overheating. See the official PDF for exact tabulated values and performance curves.
- Mechanical Seal Options: Various mechanical seal configurations (Standard, H, HS, HW, HSW, Q1AVGG, VAEGG, Q1U3EGG, U3BEGG, AQ1EGG) are available with different material combinations for rotary seal ring, stationary seal ring, O-rings, bellows, spring, and frame. See the official PDF for detailed material specifications.
- Bearings: Specific ball bearing types (e.g., 6204 2RSH, 6204-ZZ C3) are used for the pump side and fan side, varying by pump type and motor efficiency (IE2/IE3). See the official PDF for exact tabulated values.
- Thermal Insulation: Insulation for the pump casing and coupling is available as standard or on request for certain models and connection types. See the official PDF for specific configurations.
- Dimensions and Weight: Detailed dimensions (B, C, H3 in mm) and weights (kgf) for DWC-V (Victaulic connection) and DWC-N (Threaded connection) models are provided in the official PDF. See the official PDF for exact tabulated values.
- Packing: Packing dimensions (X, Y, Z in mm) and weights (kgf) are provided in the official PDF. See the official PDF for exact tabulated values.
- Noise Data:
- Sound Pressure Level (LpA): <70 dB(A)
- Tolerance: ± 2.5 dB
- Measurement: Mean value of several measures at 1m distance around the pump.