Back to Ebara Pumps
Ebara logo

Datasheet summary

Multigo

PDF datasheet mirror for Multigo (Ebara Pumps). Verify with OEM before design.

Summary

Product Identification

The EBARA MULTIGO series consists of 2-pole, 60 Hz centrifugal pumps, available in both standard and in-line versions. The in-line version is exclusively available with single-phase motors.

Operating Limits

  • Liquid Handled: Clean water
  • Max Temperature: 40 °C
  • Maximum Working Pressure: 1 MPa
  • Maximum Available Negative Suction Head: -6 m

Mechanical / Hydraulic

  • Pump Type: Closed centrifugal type (multiple stages)
  • Shaft Seal Type: Double mechanical seal
  • Bearing Type: Sealed ball bearing
  • Pipe Connection:
    • Suction: G 1¼ UNI ISO 228
    • Discharge: G 1¼ UNI ISO 228
  • Materials:
    • Casing: AISI 304
    • Casing Cover: AISI 304
    • Impeller: PPE+PS glass fibre reinforced
    • Diffuser: PPE+PS glass fibre reinforced
    • Shaft: AISI 431
    • Shaft Seal (Pump side): Carbon/Ceramic/NBR
    • Shaft Seal (Motor side): Carbon/Ceramic/NBR
    • Lubricating Oil: White mineral oil: Esso Marcol 152 (90cc)
    • Upper Bearing Bracket: Aluminium
    • Lower Bearing Bracket: Brass
    • Motor Casing Material: AISI 304
    • Mechanical Seal Components: NBR (rubber seat, rotary seal), Ceramic (stationary ring), Carbon (rotary ring), AISI 304 (coil spring, seal cover).
  • Impeller Diameter:
    • MULTIGO 40 series: 90 mm
    • MULTIGO 80 series: 85 mm
  • Bearings:
    • Pump side: 6303 ZZ
    • Fan side: 6202 ZZ
  • Construction Details: The pump features an external pump casing, casing support, and various O-rings (NBR) and washers (AISI 304). Specific quantities of impellers, diffusers, and stage housings vary by model. See the official PDF for detailed sectional views and material tables.
  • Dimensions and Weight: Pump dimensions (H) and weights are tabulated for standard and in-line versions across different models. Packing dimensions (X, Y, Z) and weights are also provided. See the official PDF for exact tabulated values.

Electrical

  • Motor Type: Submersible dry type
  • Number of Poles: 2
  • Rotation Speed: ≈ 3450 min⁻¹
  • Insulation Class: Class F
  • Protection Degree: IP X8
  • Frequency: 60 Hz
  • Voltage:
    • Single Phase: 220-230 ±6% V
    • Three Phase: 380 -6%+10% V
  • Capacitor: Built in (Single Phase), Not applicable (Three Phase)
  • Overload Protection: Built in (Single Phase), Provided by the user (Three Phase)
  • Power Cable:
    • Material: H07RN-F
    • Size (Single Phase): 3G1 (for 40/86, 40/106, 40/126, 40/156), 3G1.5 (for 80/126, 80/156)
    • Size (Three Phase): H07RN-F 4G1
    • Length: 5 m
    • Type of Cable Entry: Cable Gland
  • kW/HP Rating:
    • Single Phase: 0.6 ÷ 1.1 kW (0.8 ÷ 1.5 HP)
    • Three Phase: 0.6 ÷ 1.5 kW (0.8 ÷ 2 HP)
  • Motor Data: Detailed motor data including power (kW, HP), input (kW), full load current (A), locked rotor current (A), and capacitor (µF) are provided per model and voltage. See the official PDF for exact tabulated values.

Performance

  • Applicable Standard of Test: ISO 9006:2012 - Grade 3B
  • Test Conditions: Curves refer to effective speed of asynchronous motors at 60 Hz, 2 poles. Measurements were carried out with clean water at 20 °C temperature and with a kinematic viscosity of ν = 1 mm²/s (1 cSt).
  • Operating Range: Continuous curves indicate the recommended working range. The dotted curve is for guidance only. To prevent overheating, pumps should not be used at a flow rate below 10% of the best efficiency point.
  • Performance Range and Selection Chart: Performance data including capacity (l/min, m³/h) and total manometric head (m) are tabulated for various models. See the official PDF for exact tabulated values and performance curves.

Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the complete OEM PDF datasheet. Contractual data must always match the specific OEM PDF revision used on the project.