Back to KSB Pumps
KSB logo

Datasheet summary

Amacan S

PDF datasheet mirror for Amacan S (KSB Pumps). Verify with OEM before design.

Summary

Product identification

The KSB Amacan S is a submersible pump designed for installation in a discharge tube, operating at 50 Hz.

Designation Key Example: Amacan S 1000-655 / 25O 8 UTG2

  • Amacan: Type series
  • S: Impeller type (Mixed flow impeller)
  • 1000: Nominal diameter of the discharge tube [mm]
  • 655: Nominal impeller diameter [mm]
  • 250: Motor size
  • 8: Number of motor poles
  • UT: Motor version (Non-explosion-proof, standard, for sizes 800-535 ... 1300-820)
  • G2: Material variant (Grey cast iron, standard material variant)

Operating limits

  • Flow rate (Q): ≤ 3000 l/s (≤ 10800 m³/h)
  • Head (H): ≤ 40 m
  • Motor rating (P₂): ≤ 420 kW
  • Fluid temperature (T):
    • Material variant G2: ≤ +40 °C
    • Material variant G3 (seawater variant): ≤ +25 °C (higher temperatures on request for both)
  • Motor power reserve:
    • P₂ ≤ 30 kW: 10 % (Mains operation), 15 % (With frequency inverter)
    • P₂ > 30 kW: 5 % (Mains operation), 10 % (With frequency inverter)
  • NPSH requirements: NPSHavailable > NPSHrequired + safety allowance
    • Safety allowance: 0.5 m (up to Qopt), 1.0 m (larger than Qopt)

Feed water

The Amacan S is suitable for handling various water types, including:

  • Grey water
  • River water
  • Stormwater
  • Activated sludge (Max. dry substance 2 %)
  • Seawater
  • Brackish water

Recommendations:

  • Waste water (without long fibres and large solid particles) and surface water require pre-screening.
  • For seawater and brackish water, Material variant G3 is recommended for temperatures up to 25 °C, requiring the use of Zn anodes (anodes to be checked every 6 to 12 months).
  • Screen bar opening sizes vary by pump size; See the official PDF for exact tabulated values.

Electrical

  • Drive: Three-phase asynchronous squirrel-cage motor
  • Motor versions:
    • UA: Non-explosion-proof, standard (sizes 650-364 ... 800-505)
    • UT: Non-explosion-proof, standard (sizes 800-535 ... 1300-820)
  • Starting method: DOL (Direct On Line) or star-delta (690 V only DOL)
  • Voltage: 400 V (Optional: 500 V, 690 V)
  • Cooling: Cooled by surrounding fluid
  • Power cable:
    • Standard: S1BN8-F rubber-sheathed cable (Rated voltage 1000 V, EPR insulation, max. continuous temperature 90 °C)
    • Optional: S07RC4N8-F rubber-sheathed cable (Rated voltage 750 V, EMC screening, EPR insulation, max. continuous temperature 90 °C)
  • Cable length: 10 m (Optional: up to 50 m)
  • Cable entry: Absolutely watertight, resin-sealed
  • Monitoring equipment:
    • Winding temperature: PTC thermistor
    • Bearing temperature: PT100 on pump end (PT100 on drive end for UTG; optional PT100 on motor end for UAG)
    • Leakage inside the motor: Electrode monitoring the winding space (UAG); Electrode monitoring the winding and connection space (UTG)
    • Mechanical seal leakage: Float switch in leakage area
    • Vibration sensor: Optional internal vibration sensor (for UTG)

Mechanical / hydraulic

  • Design: Fully floodable submersible pump in discharge tube (submersible motor pump), not self-priming, close-coupled, single-stage, vertical installation.
  • Shaft seal: Two bi-directional mechanical seals in tandem arrangement, with liquid reservoir and leakage chamber.
  • Impeller type: Open or closed mixed flow impeller.
  • Bearings: Grease-lubricated rolling element bearings.
  • Materials:
    • Material variant G2 (Standard): Pump casing EN-GJL-250, Bellmouth EN-GJL-200, Impeller 1.4517 (Duplex stainless steel), Shaft 1.4021, O-ring NBR, Mechanical seal SiC/SiC (pump end) / Carbon/SiC (drive end) with NBR bellows.
    • Material variant G3 (Seawater variant): Pump casing EN-GJL-250, Bellmouth EN-GJL-200, Impeller 1.4517 (Duplex stainless steel), Shaft 1.4057, O-ring NBR (optional Viton FPM), Mechanical seal SiC/SiC (pump end) / Carbon/SiC (drive end) with NBR bellows (optional Viton FPM bellows), includes Zn anodes.
    • Casing wear ring: 1.4571 (stainless steel).
  • Coating: Surface treatment SA 2 1/2, primer coat on unfinished casting, top coat environmentally friendly KSB standard coating (RAL 5002). Special coating available on request.
  • Free passage: 116 mm in diameter (for Amacan S 1300-820, n = 580 rpm).
  • Dimensions: Detailed dimensions for pump sets and discharge tubes are provided in the official PDF for various sizes and motor configurations.
  • Installation types: Six types are available for selection, including overflow, underfloor, and above-floor discharge designs for both open and covered intake chambers (BU, CU, DU, BG, CG, DG discharge tube).
  • Scope of supply: Pump set complete with power cables, O-ring, back-up name plate.
  • Optional accessories: Support rope, accessories for cable guide installation (fitting, turnbuckle, support, shackle, cable clamps), cable support sleeves, flow-straightening vane, discharge tube.

Disclaimer: This summary is based on the extracted text and may not include all figures, footnotes, or the latest revisions from the complete OEM PDF datasheet. Contractual data must always match the specific OEM PDF revision used on the project.

Official datasheet (PDF)

Lenntech datasheet mirror

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.