Summary

Product identification

The KSB Amarex N S 32-160 is a fully floodable submersible motor pump designed for waste water applications.

  • Type Series: Amarex N
  • Impeller Type: S (Cutter)
  • Nominal Discharge Nozzle Diameter: DN 32 (32 mm)
  • Hydraulic System Size: 160
  • Nominal Impeller Diameter: 160 mm
  • Frequency: 50 Hz
  • Motor Poles: 2-pole
  • Motor Design:
    • YL: With explosion protection T4 (40 °C)
    • UL: Without explosion protection, fluid temperatures < 40 °C
  • Casing Material: G (Grey cast iron)

Operating limits

  • Flow rate (Q): ≤ 16 m³/h (≤ 4.4 l/s)
  • Head (H): ≤ 29 m
  • Fluid temperature (T): ≤ 40 °C
  • Motor rating (P₂): 1.5 kW
  • Mode of Operation:
    • S1: submerged (25 m maximum submergence)
    • S3: outside the fluid
  • Maximum Switching Frequency (DOL starting): 30 starts per hour

Feed water

The pump is designed for handling waste water in intermittent operation.

  • Fluids Handled:
    • Domestic waste water
    • Raw waste water
    • Waste water with faeces
    • Grey water
    • Waste water or grey water containing long fibres
  • Impeller: S impeller with cutter, suitable for fluids containing coarse substances and/or long fibres.
  • Free Passage: 6 mm

Electrical

  • Drive: Three-phase asynchronous squirrel-cage motor
  • Explosion Protection:
    • Motor version YL: Ex d IIB T4 Gb (for explosion-proof pump sets)
    • Motor version UL: Non-explosionproof
  • Starting Method: DOL (Direct On Line)
  • Voltage: 400 V
  • Cooling: Cooled by surrounding fluid
  • Power Cable: Rubber-sheathed cable (H07RN8-F 7G1.5²), available in 10 m and 20 m lengths.
  • Cable Entry: Absolutely watertight
  • Monitoring Equipment:
    • Winding temperature (UL motor version): Bimetal switch directly connected with the motor's control circuit (automatic reset and start-up).
    • Winding temperature (YL motor version): Bimetal switch directly connected with the motor contactor's control circuit (automatic reset and start-up); separate bimetal switch for temperature limit for explosion protection (without automatic reset), connected via a tripping unit with manual reset.
  • Technical Data (for 1.5 kW P₂):
    • Input Power (P₁): 2.05 kW
    • Rated Current (I_N): 3.40 A
    • Starting Current (I_A): 18.2 A
    • Weight: 29 kg (for 10 m cable YL versions), 33 kg (for 20 m cable UL version)

Mechanical / hydraulic

  • Design: Close-coupled, not self-priming.
  • Shaft Seal:
    • Drive end: Shaft seal ring (NBR)
    • Pump end: Uni-directional mechanical seal with liquid reservoir (SiC/SiC)
  • Bearings: Grease-lubricated, sealed for life, maintenance-free.
  • Materials (Standard Variants):
    • Casing, Intermediate Casing, Impeller: EN-GJL-250 (Grey cast iron)
    • Cutter: 1.2080.02 (K100)
    • Shaft: 1.4021 (Stainless steel)
    • Screws/Bolts: A2 (Stainless steel)
    • Elastomers: NBR
  • Connections: The pump is mounted on a DN 50 flanged duckfoot bend.
    • Discharge Line Connections: Flanged (DN 32/DN 50), Threaded (DN 32/DN 50), or Clamped (DN 32/DN 50).
    • Pipe Compatibility:
      • Steel pipes (DIN 2440 / DIN 2441) with 60.3 mm outside diameter for DN 50.
      • PVC pipes (ISO 3606) with 63 mm outside diameter for DN 50.
      • Threaded connection DN 50 - G2″.
  • Dimensions: See the official PDF for exact tabulated values and drawings.
  • Installation Types:
    • Stationary Wet Installation: Guide hoop, guide wire, single guide rail, or twin guide rail arrangements.
      • Installation depths: 1.5 m, 1.8 m, 2.1 m (guide hoop); 4.5 m (guide wire, single/twin guide rail).
    • Transportable Wet Installation: Installation depth 4.5 m.
  • Coating: Environmentally friendly KSB top coat (two-component epoxy paint), colour RAL 5002, film thickness = 80 µm.

Certifications

  • Europe: Suitable for plants to Standard EN 12050-1.
  • Europe: Amarex N DN 32 No.: 7381257-01 z.

Accessories

A range of accessories is available for installation, lifting, and electrical control.

  • Installation Parts: Duckfoot bends, anchor bolts, guide rails, claws for various stationary and transportable setups.
  • Lifting: Chains (1.4404 stainless steel) and polypropylene lifting ropes, with maximum load 160 kg, in lengths from 2 m to 10 m.
  • Pump Accessories: Flanges, PVC adapters, elbows, Storz rigid couplings, plastic hoses, hose clips, swing check valves, socket gate valves, hand pumps, and threaded flanges.
  • Electrical Accessories:
    • Control Units: LevelControl Basic 2 for single-pump and dual-pump stations, with options for float switch, 4-20 mA sensor, pneumatic, or bubbler control. Available in non-ATEX and ATEX-compliant versions.
    • Alarm Switchgears: AS 0, AS 1, AS 2, AS 4, AS 5 with various features including acoustic signals, volt-free contacts, and self-charging power supply units.
    • Control Unit Accessories: Float switches, leakage sensors, open/closed pressure bell sets, horns, alarm combinations, yellow alarm strobe lights, PC service tool, and rechargeable battery retrofit kits.
    • ATEX Compliance Note: ATEX-compliant control units are not explosion-proof and must be operated outside potentially explosive atmospheres. Intrinsic safety barriers and ATEX level switches are required for ATEX variants.