IR, IRX

PDF datasheet mirror for IR, IRX (SAER Pumps). Verify with OEM before design.

Summary

Product Identification

The SAER IR and IR4P series are close-coupled end-suction electric pumps, normalized according to EN 733 rules.

Main Components:

  • Pump body
  • Disc
  • Impeller
  • Shaft
  • Mechanical seal
  • Gasket

Available Versions and Materials (for components in contact with the liquid):

  • IR / IR4P:
    • Pump body: Cast iron EN-GJL-250
    • Impeller: Cast iron EN-GJL-250
    • Seal holding cover/disc: Cast iron EN-GJL-250
    • Shaft: Stainless steel Duplex (IR), AISI 316 (IR4P)
    • Gasket: Natural fibre
  • IR-M / IR4P-M (Marine Bronze Version):
    • Pump body: Bronze G-CuSn10
    • Impeller: Bronze G-CuSn10
    • Seal holding cover/disc: Bronze G-CuSn10
    • Shaft: Stainless steel Duplex (IR), AISI 316 (IR4P)
    • Gasket: Natural fibre
  • IRX / IRX4P (Stainless Steel Version):
    • Pump body: Stainless steel AISI 316
    • Impeller: Stainless steel AISI 316
    • Seal holding cover/disc: Stainless steel AISI 316
    • Shaft: Stainless steel Duplex (IR), AISI 316 (IR4P)
    • Gasket: Anti-acid natural fibre

Operating Limits

  • Temperature of the pumped liquid: -15°C to +120°C
  • Max environment temperature: 40°C (for higher temperatures, verify)
  • Max operation pressure: Maximum allowed pressure considering the sum of max. suction pressure and the head with null flow rate.
  • PN max standard: 10
  • PN max on request: 16 (for IR/IR4P Cast Iron, IRX/IRX4P Stainless steel up to +50°C); 14 (for IRX/IRX4P Stainless steel +50°C / +120°C)
  • Max manometric suction height: Approximately 1.5 m (characteristics reduce for heights up to 6-7 m)

Feed Water

  • Designed for continuous service with clear water (specific weight = 1000 kg/m³).

Electrical

  • Motor: Asynchronous with 2 or 4 poles and external ventilation.
  • Protection: IP55
  • Insulation: Class F
  • Standard Tensions (50 Hz frequency):
    • 220-240V up to 4 kW
    • 380-415V / 660-720V starting from 5.5 kW
  • Motor Performance Tolerances: IEC 60034-1 rules.

Mechanical / Hydraulic

  • Pump Body: Dimensions and performances according to EN 733 rules.
  • Impeller: Closed, dynamically balanced with balance holes for axial thrust.
  • Shaft: Completely in stainless steel.
  • Bearings: Greased ball bearings.
  • Flanges (UNI EN 1092-2):
    • Up to DN 150: PN16
    • From DN 200: PN10
  • Mechanical Seal: Standard (see page 152 of the official PDF for details), special seals on request.
  • Installation: Can be positioned with horizontal, sloping, or vertical axis, always with the motor upwards.
  • DN Aspiration: 50 to 100 (150 for IR4P)
  • DN Delivery: 32 to 80 (125 for IR4P)
  • Maximum Flow Rate (Qmax):
    • 275 m³/h @ 2900 1/min
    • 400 m³/h @ 1450 1/min
  • Maximum Head (Hmax):
    • 100 m @ 2900 1/min
    • 43 m @ 1450 1/min
  • Pump Performance Tolerances: UNI EN ISO 9906 Appendix A, level 1 on request.
  • Minimum Suction Pipe Diameters (for catalogue data):
    • Pump Suction DN (mm) | Suction Pipe DN (mm)
    • 50 | 80
    • 65 | 100
    • 80 | 150
    • 100 | 200
    • 125 | 250
    • 150 | 300

Hydraulic Features and Dimensions: Detailed hydraulic performance curves, electrical data (kW, HP, In(A), ls/ln), and dimensions/weights for specific models (e.g., IR32-125C, IR40-160NC/B, IR50-250NA, IR65-200NA, IR80-200A) are provided in tabulated form across multiple pages (7-16) of the official PDF. See the official PDF for exact tabulated values.

Special Versions & Accessories

Special Versions (on request):

  • Alternative constructive materials (refer to page 6 of the official PDF)
  • Different mechanical seals (refer to page 152 of the official PDF)
  • Mechanical seal normalized according to UNI EN 12756
  • Special tensions
  • 60 Hz frequency

Accessories (on request):

  • Kit counterflanges
  • Motors with PTC protection