Product identification
This document provides specifications for several series of SAER Electric Submersible Pumps, including:
- MBS Series: Enbloc Electric Submersible Pumps.
- NS-96 Series: 4” Electric Submersible Pumps.
- FS-98 Series: 4” Radial Electric Submersible Pumps with Floating Impeller.
- NS-95 Series: 4” Electric Submersible Pumps.
- NR-151 Series: 6” Radial Electric Submersible Pumps.
- NR-152 Series: 6” Radial Electric Submersible Pumps.
Operating limits
MBS Series
- Minimum liquid level: 100 mm from bottom of suction grid.
- Maximum depth of application: up to 70 m below the water level.
- Rotation speed: 2900 1/min.
NS-96, FS-98, NS-95 Series (4” Pumps)
- Rotation speed: 2900 1/min.
- Horizontal operation is possible; correct installation with relative supports is recommended to ensure proper pump function.
NR-151, NR-152 Series (6” Pumps)
- Minimum hydrostatic head level to the suction grid (m) is provided in the performance tables.
- Horizontal operation is possible with a special version of the group.
NR-152 Series only
- Rotation speed: 2900 1/min.
Mechanical / hydraulic
MBS Series
- Maximum diameter: 147 mm.
- Delivery connection: 1”1/4 G.
NS-96 Series (4” Pumps)
- Maximum diameter: 100 mm.
- Delivery connections:
- Models A, X, B: 1”1/4 G.
- Models C, DA: 2”.
FS-98 Series (4” Pumps)
- Maximum diameter: 100 mm.
- Delivery connections:
- Models A, B, C: 1”1/4 G.
- Models D, E: 2” G.
- Outlet 1”1/4 is available in carbon steel, brass, or stainless steel.
NS-95 Series (4” Pumps)
- Maximum diameter: 100 mm.
- Delivery connections:
- Models K, A, X, B, C: 1” 1/4 G.
- Models DA, E, F: 2” G.
NR-151 Series (6” Pumps)
- Maximum diameter: 150 mm.
- Delivery connections:
- Models A, B, C, D, F: 2” 1/2 G.
- Model E: 3” G.
- For pumps with impellers in pressed brass, flow rate (Q) and head (H) decrease by 5%.
- Pumps and motors can be supplied in black colour.
NR-152 Series (6” Pumps)
- Maximum diameter: 150 mm.
- Delivery connections:
- Models A, B, C: 2” 1/2 G.
- Models D, E: 3” G.
- Performance data refers to thermoplastic impellers.
- Above 25 stages, suction and delivery supports are made of spheroidal cast iron.
Electrical
NS-96, FS-98, NS-95 Series (4” Pumps)
- Motor rated power is indicated in the tables.
- 230V 3~ motors are available upon request.
- Dimensions are provided for single-phase motors.
- Pumps up to 2.2 kW can be supplied with CLE-95 series motors upon request.
NR-151, NR-152 Series (6” Pumps)
- Motor rated power is indicated in the tables.
Performance
MBS Series
Tables provide detailed performance data including flow rate (Q in U.S.g.p.m., m³/h, l/min), head (H in m), motor power (P2 in kW, HP), total absorbed power (P1 in kW), current (In in A for 230V 1~ and 400V 3~), and capacitor (C in Vc450 μF). See the official PDF for exact tabulated values.
NS-96 Series
Tables provide detailed performance data including flow rate (Q in U.S.g.p.m., m³/h, l/min), head (H in m), motor power (kW, HP), current (In in A for 3~ 400V and 1~ 230V), capacitor (C in Vc 450 μF), and total length (T in mm). See the official PDF for exact tabulated values.
FS-98 Series
Tables provide detailed performance data including flow rate (Q in U.S.g.p.m., m³/h, l/min), head (H in m), motor power (kW, HP), current (In in A for 3~ 400V and 1~ 230V), capacitor (C in Vc 450 μF), and total length (T in mm). See the official PDF for exact tabulated values.
NS-95 Series
Tables provide detailed performance data including flow rate (Q in U.S.g.p.m., m³/h, l/min), head (H in m), motor power (kW, HP), current (In in A for 3~ 400V and 1~ 230V), capacitor (C in Vc 450 μF), and total length (T in mm). See the official PDF for exact tabulated values.
NR-151 Series
Tables provide detailed performance data including flow rate (Q in U.S.g.p.m., m³/h, l/min), head (H in m), motor power (kW, HP), current (In in A for 3~ 400V), and total length (T in mm). See the official PDF for exact tabulated values.
NR-152 Series
Tables provide detailed performance data including flow rate (Q in U.S.g.p.m., m³/h, l/min), head (H in m), motor power (kW, HP), current (In in A for 3~ 400V), and total length (T in mm). See the official PDF for exact tabulated values.
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the original OEM PDF datasheet. Contractual data must always match the specific OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.