Back to SAER Pumps
SAER logo

Datasheet summary

T-ONE

PDF datasheet mirror for T-ONE (SAER Pumps). Verify with OEM before design.

Summary

Product Identification

The T-ONE Compact Pressurization System is an exclusive and patented electronic pressurization system created by SAER. It features a submersible electric pump housed within a stainless steel tank, controlled by electronic equipment to maintain consistent output pressure regardless of flow demand.

Key features include:

  • Compact: Condensed design with in-line installation, eliminating the need for floor fastening.
  • Electronic: Equipped with an electronic system (inverter) for constant pressure operation and modular multi-pump functionality.
  • Energy Saving: Automatic regulation based on water demand.
  • Modular: Up to 8 modules can be operated in parallel, added at any time, and communicate via Bluetooth without requiring electrical cables.
  • Silent and Efficient: Operates at a quiet 60 dB, utilizing NS96 pumps for high efficiency.
  • Safe: Includes all necessary protections.
  • Performance: Available in 5 different sizes for a wide range of performance.
  • Patented: Original design.
  • Easy: Simple and intuitive installation and programming.
  • Quality: Made in Italy.

Operating Limits

  • Liquid temperature: Min -15°C, Max 35°C
  • Environment conditions: Must be installed indoors
  • Environment temperature: Min 0°C, Max 50°C
  • Protection grade: IP55
  • Noiseless: Max 60 dBA
  • Maximum running pressure: 10 bar (maximum admissible pressure, considering the sum of maximum suction pressure and head once shut off).
  • Pressure transducer range: 0-16 bar

Feed Water

  • Fluid: Chemically and mechanically not aggressive.

Product Water

The system is designed for water distribution and pressurization in civil, agricultural, and industrial applications, maintaining constant output pressure.

Electrical

The T-ONE system is electronic, featuring an inverter-driven submersible pump. In multi-pump configurations, inverters communicate via Bluetooth.

The unit display provides information on:

  • Current intensity (instantaneous current consumption - A)
  • Net tension applied (V)
  • Running pressure (bar)
  • Running frequency of the motor-pump group
  • Operating state of the main pump (by LED)
  • Type of alarm in case of damage

Safeguards include:

  • Dry running and associated alarm
  • Overload (overworking) alarm
  • Minimum/maximum tension alarm
  • Overheating of the inverter alarm

Mechanical / Hydraulic

The T-ONE is a self-standing unit with "in-line" inlet and outlet connections, including an integrated check valve on the delivery.

Performance Overview:

  • Flow: Max 15 m³/h
  • Head: Max 110 m
  • Typical Performance: 3 bar at 15 m³/h

Dimensions (Standard T-ONE version):

  • Height (H): 1200 mm
  • Length (L): 322 mm
  • Depth (D): 322 mm
  • Weight: 45 kg
  • Inlet/Outlet Connections: G 2"

Hydraulic Performance Data: The datasheet includes detailed tables listing various T-ONE models (e.g., T1-96 A5, T1-96 A7, T1-96 X5, T1-96 X7, T1-96 B4, T1-96 B6, T1-96 C5, T1-96 C7, T1-96 DA4, T1-96 DA5, and T1+-96 A5, T1+-96 A7, T1+-96 B4) with their respective motor power (kW and HP), and corresponding head (H in m) at different flow rates (Q in m³/h and l/min). See the official PDF for exact tabulated values.

Performance curves are based on:

  • Kinematic viscosity = 1 mm²/s
  • Density = 1000 kg/m³
  • Water temperature = 20°C
  • Tolerance and curves according to UNI EN ISO 9906:2012 – Grade 3B.

Optional Accessories

  • Expansion tanks with a membrane on the delivery manifolds
  • Manifolds and valves

Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the complete OEM PDF datasheet. Contractual data must always match the specific OEM PDF revision used for the project.