Back to Koch Membrane Systems (Fluid Systems™)
Kovalus logo

Datasheet summary

ROGA-4040-HR 4"

Engineering summary from PDF text extraction for ROGA-4040-HR 4\". Verify every value with the OEM datasheet.

Summary

Product identification

ROGA®-HR 4” Elements are Cellulose Acetate RO Elements.

  • Membrane Chemistry: Proprietary ROGA® cellulose acetate
  • Membrane Type: ROGA®-HR membrane
  • Construction: Spiral wound with fiberglass outerwrap
  • Applications: High rejection for municipal water treatment, municipal wastewater reclamation, industrial water supply, and where chlorine is needed on a regular basis

Specifications

The specifications for the ROGA-4040-HR model are:

  • Part Number: 8422100
  • Model: ROGA-4040-HR
  • Permeate Flow: 1,700 gpd (6.4 m³/d)
  • Chloride Rejection: 98.0 percent
  • Active Membrane Area: 80 ft² (7.4 m²)
  • Feed Spacer: 31 mil (0.8 mm)

Test Conditions: 2,000 mg/l NaCl solution at 420 psi (2,900 kPa) applied pressure, 15% recovery, 77°F (25°C) and pH 5.7.

Performance Note: Individual element permeate flows may vary +15/-15% from the nominal values. Minimum chloride ion rejection is 97% under the stated test conditions.

Operating limits

  • Typical Operating Pressure: 420 psi (2,900 kPa)
  • Maximum Operating Pressure: 600 psi (4,140 kPa)
  • Maximum Operating Temperature: 104°F (40°C)
  • Maximum Cleaning Temperature: 104°F (40°C)
  • Maximum Continuous Free Chlorine: 1 mg/l free chlorine equivalent (or similarly active oxidizing agents such as iodine, bromine, and ozone)
  • Allowable pH – Continuous Operation: 4 - 6
  • Allowable pH – Short Term Cleaning: 2.5 - 7 (recommended to limit exposure to 4 hours, once per month)
  • Permeate Pressure: Should not exceed feed-concentrate pressure by more than 5 psi (34 kPa) at any time.
  • Maximum Differential Pressure per Element: 10 psi (69 kPa)
  • Maximum Differential Pressure Per Vessel: 60 psi (414 kPa)
  • Maximum Feed Turbidity: 1 NTU (Feedwater with turbidity greater than 0.2 NTU generally results in frequent cleanings.)
  • Maximum Feed SDI (15 minute test): 5.0
  • Recovery: Maximum recovery is site and application specific. Single element recovery is approximately 15%.

Feed water

  • pH Adjustment: Feedwater pH should be adjusted to a practical value of approximately 5.7 to minimize membrane hydrolysis. Above pH 6, these effects may become significant and may reduce the effective life of a membrane.
  • Feed Spacers: The use of 31 mil thick feed spacers (standard construction) is recommended for applications where the feedwater has higher fouling potential.

Mechanical / hydraulic

  • Model: ROGA 4040-HR
  • Length (A): 40 inches (1,016 mm)
  • Diameter (B): 4 inches (101.6 mm)
  • Center Tube Diameter (C): 0.625 inches (15.9 mm)
  • Weight: 10 lbs (4.5 kg)
  • Interconnector Part Number: 0035262
  • O-ring Part Number: 0035468
  • Brine Seal Part Number: 0035702

Note: Dimensions are provided for reference only and should not be interpreted as accurate specifications.

Lubricants

For element loading, use only the recommended silicone lubricant (or approved equivalent), water, or glycerin to lubricate O-rings and brine seals. The use of petroleum-based lubricants or vegetable-based oils may damage the element and void the warranty.