Datasheet summary
TFC-4040-HF 4" High Rejection, High Flow
Engineering summary from PDF text extraction for TFC-4040-HF 4\" High Rejection, High Flow. Verify every value with the OEM datasheet.
Summary
Product identification
- Membrane Chemistry: Proprietary TFC® polyamide
- Membrane Type: TFC®-HF membrane
- Construction: Spiral wound with fiberglass outerwrap
- Applications: Seawater desalination
Specifications
| Part Number | Model | Permeate Flow gpd (m³/d) | Chloride Rejection percent | Active Membrane Area ft² (m²) | Feed Spacer mil (mm) |
|---|---|---|---|---|---|
| 8182002 | 4040-HF | 1,760 (6.6) | 99.7 | 74 (6.9) | 31 (0.8) |
Test Conditions: 32,800 mg/l NaCl solution (isosmotic to ASTM standard seawater) at 800 psi (5,520 kPa) applied pressure, 7% recovery, 77°F (25°C) and pH 7.5.
Performance
Performance specifications are nominal values. Individual element permeate flows may vary ±15% from the values shown. Minimum rejection is 99.3% at the conditions shown.
Operating limits
- Typical Operating Pressure: 750 - 950 psi (5,175 - 6,555 kPa)
- Maximum Operating Pressure: 1,000 psi (6,896 kPa)
- Maximum Operating Temperature: 113°F (45°C)
- Maximum Cleaning Temperature: 113°F (45°C)
- Maximum Continuous Free Chlorine: <0.1 mg/l
- Allowable pH – Continuous Operation: 4 - 11
- Allowable pH – Short Term Cleaning: 2.5 - 11 (exposure to extended pH range limited to 4 hours, once per month)
- Maximum Differential Pressure Per Element: 10 psi (69 kPa)
- Maximum Differential Pressure Per Vessel: 60 psi (414 kPa)
- Maximum Feed Turbidity: 1 NTU (feedwater with turbidity >0.2 NTU generally results in frequent cleanings)
- Maximum Feed SDI (15 minute test): 5
- Permeate Pressure: Should not exceed feed-concentrate pressure by more than 5 psi (34 kPa) at any time.
- Recovery: Single element recovery is approximately 7% per element. Maximum recovery is site and application specific.
Chemical Tolerance
- Chlorine:
- Exposure to free chlorine or other oxidizing agents (e.g., permanganate, ozone, bromine, iodine) is not recommended.
- Free chlorine tolerance of approximately 1,000 ppm-hours based on testing at 77°F (25°C), pH 8. This tolerance may be significantly reduced if catalyzing metals (e.g., iron) are present or if pH and/or temperature differ.
- Sodium metabisulfite (without catalysts such as cobalt) is the preferred reducing agent.
- Chloramine tolerance of approximately 60,000 ppm-hours in the absence of free chlorine based on testing at 77°F (25°C), pH 8.
- Cationic Polymers and Surfactants: May cause irreversible fouling; exposure during operation or cleaning is not recommended.
- Lubricants: For element loading, use only approved silicone lubricant, water, or glycerin. Petroleum-based lubricants or vegetable-based oils may damage the element and void the warranty.
Mechanical / Hydraulic
Nominal Dimensions and Weight (for reference only)
| Model | A inches (mm) | B inches (mm) | C inches (mm) | D inches (mm) | Weight lbs (kg) | Interconnector | O-ring | Brine Seal |
|---|---|---|---|---|---|---|---|---|
| 4040-HF | 40 (1,016) | 4 (101.6) | 0.75 (19.0) | 1.0 (25.4) | 10 (4.5) | 0035267 | 0035458 | 0035702 |