Datasheet summary
TFC-4040-HR 4" Hig Rejection, Low Pressure
Engineering summary from PDF text extraction for TFC-4040-HR 4\" Hig Rejection, Low Pressure. Verify every value with the OEM datasheet.
Summary
Product identification
FLUID SYSTEMS® TFC®- HR 4” ELEMENT High Rejection, Low Pressure RO Element for Brackish Water.
- Membrane Chemistry: Proprietary TFC® polyamide
- Membrane Type: TFC®-HR membrane
- Construction: Spiral wound element
- Applications: High rejection for brackish water treatment
- Options: Fiberglass overwrap or tape overwrap (-T)
Specifications
| Part Number | Model | Permeate Flow gpd (m³/d) | Chloride Rejection percent | Active Membrane Area ft² (m²) | Feed Spacer mil (mm) |
|---|---|---|---|---|---|
| 8482000 | 4040-HR | 2,270 (8.6) | 99.55 | 85 (7.9) | 28 (0.7) |
| 8404000 | 4040-HR-T | 2,270 (8.6) | 99.55 | 85 (7.9) | 28 (0.7) |
Test Conditions: 2,000 mg/l NaCl solution at 225 psi (1,550 kPa) applied pressure, 15% recovery, 77°F (25°C) and pH 7.5.
Performance Notes:
- Performance specifications shown are nominal values.
- Individual element permeate flows may vary ±15% from the values shown.
- Minimum chloride ion rejection is 99.2% at the specified test conditions.
- System performance should be predicted using KMS ROPRO® software.
- System operating data should be normalized and key performance parameters tracked using KMS NORMPRO® software.
Operating limits
- Typical Operating Pressure: 150 - 250 psi (1,035 - 1,725 kPa)
- Maximum Operating Pressure: 600 psi (4,140 kPa)
- Maximum Operating Temperature: 113°F (45°C)
- Maximum Cleaning Temperature: 113°F (45°C)
- Maximum Continuous Free Chlorine: <0.1 mg/l
- Allowable pH – Continuous Operation: 4 - 11
- Allowable pH – Short Term Cleaning: 2.5 - 11 (Recommended to limit exposure to extended pH range to 4 hours, once per month.)
- Maximum Differential Pressure Per Element: 10 psi (69 kPa)
- Maximum Differential Pressure Per Vessel: 60 psi (414 kPa) for FRP overwrap; 30 psi (207 kPa) for tapewrap elements.
- Permeate Pressure: Should not exceed feed-concentrate pressure by more than 5 psi (34 kPa) at any time.
- Recovery: Maximum recovery is site and application specific. Single element recovery is approximately 15% per element. Recovery limits should be determined using KMS ROPRO® program.
- Chemical Tolerance (Chlorine): Exposure of TFC-HR membrane to free chlorine or other oxidizing agents is not recommended. Free chlorine tolerance is approximately 1,000 ppm-hours based on testing at 77°F (25°C), pH 8. This tolerance may be reduced if catalyzing metals (e.g., iron) are present or if pH/temperature differ. Sodium metabisulfite is the preferred reducing agent. Chloramine tolerance is approximately 60,000 ppm-hours (in absence of free chlorine) based on testing at 77°F (25°C), pH 8.
- Chemical Tolerance (Cationic Polymers and Surfactants): Exposure to cationic (positively charged) polymers or surfactants is not recommended as it may irreversibly foul the membrane.
- Lubricants: For element loading, use only recommended silicone lubricant (or approved equivalent), water, or glycerin for O-rings and brine seals. Petroleum-based or vegetable-based oils may damage the element and void the warranty.
Feed water
- Maximum Feed Turbidity: 1 NTU (Experience suggests feedwater with turbidity >0.2 NTU generally results in frequent cleanings.)
- Maximum Feed SDI (15 minute test): 5
Mechanical / hydraulic
Nominal Dimensions and Weight (Dimensions are provided for reference only.)
| Model | A inches (mm) | B inches (mm) | C inches (mm) | D inches (mm) | Weight lbs (kg) | Interconnector | O-ring | Brine Seal |
|---|---|---|---|---|---|---|---|---|
| 4040-HR | 40 (1,016) | 4 (101.6) | 0.75 (19.0) | 1.0 (25.4) | 10 (4.5) | 0035267 | 0035458 | 0035702 |
| 4040-HR-T | 40 (1,016) | 4 (101.6) | 0.75 (19.0) | 1.0 (25.4) | 10 (4.5) | 0035267 | 0035458 | 0035702 |
Maximum Number Of Tape Wrap Elements Per Vessel: 3