Back to Koch Membrane Systems (Fluid Systems™)
Kovalus logo

Datasheet summary

TFC-4040-XR 4" High Rejection, Low Pressure

Engineering summary from PDF text extraction for TFC-4040-XR 4\" High Rejection, Low Pressure. Verify every value with the OEM datasheet.

Summary

Product identification

  • Product Name: FLUID SYSTEMS® TFC®- XR 4” ELEMENT
  • Description: High Rejection, Low Pressure RO Element for Brackish Water
  • Membrane Chemistry: Proprietary TFC® polyamide
  • Membrane Type: TFC®-XR membrane
  • Construction: Spiral wound with fiberglass outerwrap
  • Applications: High rejection for brackish water treatment
  • Model: 4040-XR
  • Part Number: 8482001

Specifications (Nominal)

  • Permeate Flow: 2,200 gpd (8.3 m³/d)
  • Chloride Rejection: 99.75%
  • Active Membrane Area: 85 ft² (7.9 m²)
  • Feed Spacer: 28 mil (0.7 mm)

Test Conditions: 2,000 mg/l NaCl solution at 325 psi (2,240 kPa) applied pressure, 15% recovery, 77°F (25°C), and pH 7.5. Individual element permeate flows may vary +20/-15% from nominal values. Minimum chloride ion rejection is 99.2% under the specified test conditions.

Operating limits

  • Typical Operating Pressure: 225 - 450 psi (1,550 - 3,100 kPa)
  • Maximum Operating Pressure: 600 psi (4,140 kPa)
  • Maximum Operating Temperature: 113°F (45°C)
  • Maximum Cleaning Temperature: 113°F (45°C)
  • Permeate Pressure: Should not exceed feed-concentrate pressure by more than 5 psi (34 kPa) at any time.
  • Maximum Differential Pressure per Element: 10 psi (69 kPa)
  • Maximum Differential Pressure per Vessel: 60 psi (414 kPa)
  • Allowable pH – Continuous Operation: 4 - 11
  • Allowable pH – Short Term Cleaning: 2.5 - 11 (It is recommended to limit exposure to this extended pH range to 4 hours, once per month.)
  • Recovery: Single element recovery is approximately 15% per element (site and application specific).

Feed water

  • Maximum Continuous Free Chlorine: <0.1 mg/l
    • TFC-XR membrane has a free chlorine tolerance of approximately 1,000 ppm-hours based on testing at 77°F (25°C), pH 8. This tolerance may be significantly reduced if catalyzing metals (e.g., iron) are present or if pH and/or temperature differ.
    • Chloramine tolerance is approximately 60,000 ppm-hours in the absence of free chlorine based on testing at 77°F (25°C), pH 8.
  • Maximum Feed Turbidity: 1 NTU (Feedwater with turbidity greater than 0.2 NTU generally results in frequent cleanings).
  • Maximum Feed SDI (15 minute test): 5.0
  • Chemical Tolerance: Exposure to cationic (positively charged) polymers or surfactants during operation or cleaning is not recommended as it may cause irreversible fouling.

Mechanical / hydraulic

  • Nominal Dimensions (for 4040-XR):
    • A: 40 inches (1,016 mm)
    • B: 4 inches (101.6 mm)
    • C: 0.75 inches (19.0 mm)
    • D: 1.0 inches (25.4 mm)
  • Weight: 10 lbs (4.5 kg)
  • Associated Parts:
    • Interconnector Part Number: 0035267
    • O-ring Part Number: 0035458
    • Brine Seal Part Number: 0035702
  • Lubricants: For element loading, use only the recommended silicone lubricant (or approved equivalent), water, or glycerin to lubricate O-rings and brine seals. The use of petroleum-based lubricants or vegetable-based oils may damage the element and void the warranty.

Disclaimer: This summary is based on the provided text extraction and may not include all figures, footnotes, or the latest revisions from the original OEM PDF. Contractual data must match the specific OEM PDF revision used for the project.