Datasheet summary
Puron PSH 250
Engineering summary from PDF text extraction for Puron PSH 250. Verify every value with the OEM datasheet.
Summary
Product identification
- Product Line: PURON® HOLLOW FIBER MODULES
- Application: Hollow Fiber Submerged Membrane Modules for MBR Applications
- Membrane Chemistry: Proprietary PVDF
- Membrane Type: Braided hollow fiber for outside-in operation
- Fiber Support Chemistry: Polyester
- Nominal Pore Size: 0.03 µm
- Outside Fiber Diameter: 0.1 inch (2.6 mm)
- Regulatory Information: Accepted by California Department of Public Health (CDPH) for compliance with California Water Recycling Criteria (Title 22)
- Potting Material: Proprietary epoxy compound
- Module Frame Material: 316 Stainless Steel
- Permeate Collection Tube Material: ABS, PVC, PE manifolds
- Storage Solution: Glycerin
Product specifications
| Model | Membrane Area ft² (m²) | Rows per Module |
|---|---|---|
| PSH 250 | 2,690 (250) | 8 |
| PSH 300 | 3,230 (300) | 8 |
| PSH 500 | 5,380 (500) | 16 |
| PSH 600 | 6,460 (600) | 16 |
| PSH 1500 | 16,150 (1,500) | 44 |
| PSH 1800 | 19,375 (1,800) | 44 |
Operating limits
- Temperature Range: 41 - 104°F (5 - 40°C)
- Maximum Filtration Transmembrane Pressure: 9 psi (0.6 bar)
- Maximum Backflush Transmembrane Pressure: 9 psi (0.6 bar)
- Allowable pH Range for Cleaning: 2.0 – 10.5
- Maximum Allowed Total Chlorine @ 95°F (35°C) or Lower:
- 1,000 ppm @ pH 8 or higher during maintenance clean
- 2,000 ppm @ pH 8 or higher during recovery clean
- Maximum Allowed Total Chlorine Contact: 500,000 ppm-hrs cumulative
Mechanical / hydraulic
Nominal Dimensions & Weight
| Model | L Inches (mm) | W Inches (mm) | H Inches (mm) | Dry Weight Pounds (kg) |
|---|---|---|---|---|
| PSH 250 | 35.67 (906) | 35.16 (893) | 93.82 (2,384) | 660 (300) |
| PSH 300 | 35.67 (906) | 35.16 (893) | 93.82 (2,384) | 715 (325) |
| PSH 500 | 65.43 (1,662) | 35.16 (893) | 95.35 (2,422) | 1,210 (550) |
| PSH 600 | 65.43 (1,662) | 35.16 (893) | 95.35 (2,422) | 1,265 (575) |
| PSH 1500 | 88.35 (2,244) | 69.10 (1,755) | 99.61 (2,530) | 2,860 (1,300) |
| PSH 1800 | 88.35 (2,244) | 69.10 (1,755) | 99.61 (2,530) | 3,434 (1,570) |
Connections
| Model | Permeate Type | Permeate Outside Diameter (mm) | Air Type | Air Outside Diameter (mm) |
|---|---|---|---|---|
| PSH 250 | Flange | DN 50 | Flange | DN 50 |
| PSH 300 | Flange | DN 50 | Flange | DN 50 |
| PSH 500 | Flange | DN 80 | Flange | DN 80 |
| PSH 600 | Flange | DN 80 | Flange | DN 80 |
| PSH 1500 | Pipe | Ø 200 | Pipe | Ø 110 |
| PSH 1800 | Pipe | Ø 200 | Pipe | Ø 110 |
Storage and Handling
- Storage of PURON Modules:
- Ambient temperature: 41 to 77°F (5 to 25°C).
- Avoid extended exposure to UV.
- Do not store for longer than 3 months on site.
- Transport of PURON Modules:
- Ambient temperature: 23 to 113°F (-5 to 45°C).
- For ship transport, use seaworthy packaging.
- Dry-up Protection:
- Once commissioned with aqueous medium, modules should never be stored dry.
- For idle periods of 7 days or less, keep submerged in aerated, recirculated, healthy biomass, with module aeration every 30 minutes for 1 minute to assure sludge mixing.
- Storage of Used Modules (idle period > 7 days):
- Submerge fully in potable water, aerate 3-4 hours, drain, and refill with fresh water.
- Add sodium hypochlorite to achieve 10 mg/L total chlorine at pH 5.5-7.5.
- Check chlorine daily; if below 5 mg/L, add more sodium hypochlorite.
- Long-term Storage (idle period > 21 days or dry-up unavoidable): Consult KMS for details.
- Proper Handling: Exercise utmost care; avoid collisions, impact, or rough handling.
- Precautions When Working Near the Hollow Fiber Module: Keep modules free from sharp objects or heat sources. Prohibit actions causing sparks (e.g., welding, grinding).
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions. Contractual data must match the OEM PDF revision used on the project.