Romicon 1" PM5 Hollow Fiber

Engineering summary from PDF text extraction for Romicon 1\" PM5 Hollow Fiber. Verify every value with the OEM datasheet.

Summary

Product identification

ROMICON® 1" Hollow Fiber Cartridges are ultrafiltration cartridges designed for filtration of process streams within a separation range of 5,000 to 500,000 Daltons. They are crossflow-type filters to minimize solids cake buildup and provide efficient filtration at low operating pressure.

  • Membrane Polymer: Polysulfone
  • Housing Construction: Polysulfone
  • Seal/Potting Material: Proprietary Epoxy Compound
  • Storage Solution: Glycerin

Options:

  • Lumen sizes: 20 mil (0.5 mm), 43 mil (1.1 mm), 60 mil (1.5 mm), 75 mil (1.9 mm), 106 mil (2.7 mm)
  • Membrane Types: PM5, PM10, PM30, PM50, PM100, or PM500
  • ROMIPRO™ Cartridges: Selected cartridges of all membrane types are available with components that have passed USP Class VI test guidelines.

Cartridge availability and Membrane Area

The following membrane types are available with specific fiber diameters:

Membrane TypeMWCO (Dalton) or Pore size (µm)Fiber Diameter Availability (mil / mm)
PM55,00043 mil (1.1 mm)
PM1010,00020 mil (0.5 mm), 43 mil (1.1 mm), 60 mil (1.5 mm)
PM3030,00043 mil (1.1 mm)
PM5050,00043 mil (1.1 mm), 60 mil (1.5 mm), 75 mil (1.9 mm)
PM100100,00020 mil (0.5 mm), 43 mil (1.1 mm)
PM500500,00043 mil (1.1 mm), 75 mil (1.9 mm), 106 mil (2.7 mm)

Membrane Area by Fiber Diameter:

  • 20 mil (0.5 mm): 2.0 ft² (0.18 m²)
  • 43 mil (1.1 mm): 1.0 ft² (0.09 m²)
  • 60 mil (1.5 mm): 1.0 ft² (0.09 m²)
  • 75 mil (1.9 mm): 0.8 ft² (0.07 m²)
  • 106 mil (2.7 mm): 0.7 ft² (0.06 m²)

Operating limits

  • Maximum Operating Pressure: 40 psi (2.8 bar) (or 100 psi if permeate side is pressurized)
  • Maximum Transmembrane Pressure: 30 psi (2.1 bar)
  • Maximum Operating Temperature: 140°F (60°C) (at pH 6.0)
  • Maximum Cleaning Temperature: 130°F (54°C)
  • Maximum Permeate Side Back Pressure: 20 psi (1.4 bar) (Permeate pressure should not exceed this at any time, including backflush.)
  • Maximum Differential Pressure (Feed Side / per cartridge): 30 psi (2.1 bar)
  • Allowable pH (general operation): 1.5 – 13.0 @ 130°F (54°C)
  • Allowable pH (for cleaning): 1.5 – 13.0
  • Maximum Total Chlorine (During Cleaning): 200 ppm @ pH 10-10.5, 130°F (54°C); 0 ppm @ pH < 9.5

Consult KMS Process Technology Group for specific applications.

Nominal dimensions

  • Model: 1018
    • Permeate Connection: ⅜” hose
    • Process Connection: ¾” T/C

Product Nomenclature

The product nomenclature follows a standard field format:

  • Field 1: HF – Hollow fiber cartridge
  • Field 2 (optional): Market or application designation
  • Field 3: Cartridge diameter times 10 in inches
  • Field 4: Cartridge length in inches
  • Field 5: Active membrane area in ft²
  • Field 6: Fiber diameter in mils (1000 mil = 1 inch)
  • Field 7: Molecular Weight Cutoff divided by 1000 in Daltons

Lubricants

For cartridge installation, use only water or glycerin to lubricate seals. Petroleum or vegetable-based oils or solvents may damage the cartridge and will void the warranty.


Disclaimer: This summary is based on the provided text extract. The original OEM PDF datasheet may contain additional figures, footnotes, or more recent revisions. For contractual data, always refer to the specific OEM PDF revision used on your project.