Back to Koch Membrane Systems (Fluid Systems™)
Kovalus logo

Datasheet summary

Spirapro HFK 4333-K131-VSV Pharmaceutical

Engineering summary from PDF text extraction for Spirapro HFK 4333-K131-VSV Pharmaceutical. Verify every value with the OEM datasheet.

Summary

Product identification

SPIRAPRO™ HFK™ PHARMACEUTICAL GRADE UF ELEMENTS are ultrafiltration 4-inch and 8-inch spiral element series.

  • Membrane Chemistry: Proprietary semi-permeable polyethersulfone (PES)
  • Membrane Type:
    • HFK™-131 with observed separation range of 10,000 Daltons
    • HFK™-328 with observed separation range of 5,000 Daltons
  • Construction: Sanitary spiral wound element with net outer wrap
  • Feed Spacer: V (46 mil)
  • Permeate Tube: Stainless steel
  • Applications: Enzyme purification, protein concentration, and protein fractionation
  • Regulatory Status: Conform to FDA food-contact regulations (CFR Title 21)
  • Options:
    • Outer wrap: Controlled (VSV) or trimmable (VST)
    • Diameter: 4.3” or 8.3”
  • Active Membrane Area:
    • SPIRAPRO,4333-K131-VSV: 75 ft² (7.0 m²)
    • SPIRAPRO,8333-K131-VST: 278 ft² (25.8 m²)
    • SPIRAPRO,8333-K328-VST: 286 ft² (26.6 m²)
  • Pure Water Flux: 1.0-2.2 gfd/psi (24-53 l/m²/h/bar) at 77°F (25°C)

Operating limits

  • Typical Operating Pressure: 30 - 120 psi (2.1 - 8.3 bar)
  • Maximum Operating Pressure: 140 psi (9.7 bar)
  • Operating Temperature Range: 41 - 131°F (5 - 55°C)
  • Cleaning Temperature Range: 105 - 122°F (40 - 50°C)
  • Allowable pH - Continuous Operation: 2.0 - 10.0
  • Allowable pH - Clean-In-Place (CIP): 1.8 - 11.0

Feed water

  • Turbidity: Maximum 1 NTU
  • SDI: Maximum 5.0 (15-minute test)

Mechanical / hydraulic

  • Design Pressure Drop Per Element: 15-20 psi (1.0-1.4 bar)
  • Design Pressure Drop Per Vessel (3 in series): 45-60 psi (3.1-4.1 bar)
  • Design Pressure Drop Per Vessel (4 in series): 60-68 psi (4.1-4.7 bar)
  • Nominal Dimensions (reference only):
    • 4333 models:
      • A: 37.0 inches (940 mm)
      • B: 4.3 inches (109 mm)
      • C: 0.811 inches (20.6 mm)
      • D: 33.0 inches (838 mm)
    • 8333 models:
      • A: 36.7 inches (933 mm)
      • B: 8.3 inches (211 mm)
      • C: 1.632 inches (41.5 mm)
      • D: 33.0 inches (838 mm)

Special Conditions / Warnings

  • Permeate Pressure: Should not exceed baseline (concentrate) pressure at any time. Reverse pressure will damage the membrane.
  • Chlorine Exposure:
    • Recommended exposure time: 30 minutes per day.
    • Residual chlorine concentration during CIP: 150 ppm @ pH 10.5 or higher.
    • Maximum chlorine concentration: 200 ppm.
    • Chlorine should only be added to the cleaning solution after pH has been adjusted to 10.5 or higher.
    • Iron or other catalyzing metals in the presence of free chlorine or hydrogen peroxide will accelerate membrane degradation.
  • Cationic Polymers and Surfactants: Exposure may irreversibly foul HFK membranes and is not recommended. It will void the warranty.
  • Lubricants: For element installation, use only water or glycerin to lubricate seals. Petroleum or vegetable-based oils or solvents may damage the element and will void the warranty.