Targa 8072-742-20-PM10 Hollow Fiber

Engineering summary from PDF text extraction for Targa 8072-742-20-PM10 Hollow Fiber. Verify every value with the OEM datasheet.

Summary

Product identification

  • Product Type: TARGA® PM10 HOLLOW FIBER CARTRIDGES
  • Application: 8-inch Industrial Water Ultrafiltration Cartridges
  • Membrane Chemistry: Proprietary semi-permeable polysulfone
  • Membrane Type: PM10
  • Housing Shell/End Caps: Proprietary polysulfone
  • Fiber Support Netting: Polypropylene/Polyethylene
  • Permeate Collection Tube: PVC
  • Potting Material: Proprietary epoxy compound
  • Preservative: Glycerin

Product Specifications

ModelPart NumberNominal MWCOProduction Range gpm (m³/hr)
TARGA® 8072-742-20-PM10072041310,00048.2 (10.9) - 22.7 (5.2)
TARGA® 8072-367-43-PM10072041510,00023.4 (5.3) - 11.0 (2.5)

Note: Higher production can be expected for post IX/RO polishing applications.

Operating limits

  • Maximum Pressure (water): 45 psi (3.0 bar) @ 104º F (40º C) or less
  • Temperature Range: 32º F (0º C) - 104º F (40º C)
  • Maximum Production Transmembrane Pressure: 30 psi (2.1 bar)
  • Maximum Backflush Transmembrane Pressure: 20 psi (1.4 bar)
  • Maximum Total Chlorine @ 77º F (25º C) or lower: 200 ppm @ 9.5 pH or higher during intermittent backflush
  • Maximum Total Chlorine Contact: 200,000 ppm-hrs cumulative

Consult KMS Process Engineering Group for specific applications.

Mechanical / hydraulic

Nominal Dimensions

ModelFiber Diameter (ID)Membrane AreaD Inches (mm)L Inches (mm)
TARGA® 8072-742-20-PM100.020 inch (0.5 mm)742 ft² (68.9 m²)8.4 (213)72 (1829)
TARGA® 8072-367-43-PM100.043 inch (1.1 mm)367 ft² (34.1 m²)8.4 (213)72 (1829)

Assembly Components

  • 8” HF Cartridge (1 each)
  • Leveling Hardware (Screw ½ ” X 13) (2 each) – Part Number: 1002443
  • Leveling Hardware (Nut ½ “ X 13) (2 each) – Part Number: 1002443
  • 8” Coupling Set (gasket included) (2 each) – Part Number: 0151303
  • O-Ring, Permeate Adapter (8 each) – Part Number: 0211022
  • Permeate Adapter (2 each) – Part Number: 1002655
  • 2” Coupling Set (gasket included) (2 sets) – Part Number: 0151304 / 0151261
  • Kit Process Pass for 8” cartridge – Part Number: 0220158

Storage Conditions

  • New cartridges:
    • Impregnated with glycerin. Remove glycerin before initial use with a rinse, followed by a caustic wash, and then a caustic/chlorine wash.
    • Store in original shipping containers and crates:
      • Indoors, out of direct sunlight.
      • At temperatures between 50 – 85 °F (10 – 30 °C).
      • At relative humidity below 70%.
      • In a horizontal position.
  • Used cartridges:
    • Cleaned, rinsed, and impregnated before storage with one of the following solutions:
      • Glycerin @ 80 – 100%
      • Phosphoric acid @ pH 2 – 3
      • Benzoic acid or sodium benzoate @ 1,000 ppm
      • Sodium bisulfite or sodium metabisulfite @ 1,000 – 5,000 ppm
    • Cartridges stored in sodium bisulfite or sodium metabisulfite should be flushed with clean water and impregnated with fresh solution at six-month intervals.
    • Once impregnated, leave cartridges on the system with all valves closed, or remove from the system and seal in plastic bags.
    • Storage conditions described for new cartridges also apply to used cartridges.
    • Cartridges must be drained, rinsed, and cleaned after storage per the pre-startup cleaning instruction sheet.