Winefilter II 5043 Hollow Fiber Crossflow
Engineering summary from PDF text extraction for Winefilter II 5043 Hollow Fiber Crossflow. Verify every value with the OEM datasheet.
Summary
Product identification
These are KMS WINEFILTER™ II 5” Hollow Fiber Cartridges, designed for wine filtration applications.
- Product Type: Hollow Fiber Crossflow Cartridges
- Membrane Material: Polysulfone
- Regulatory Status: Conforms to FDA regulations (CFR Title 21)
- Housing Construction: Polysulfone shell and end caps
- Storage Solution: Glycerin
Specifications
- WINEFILTER II 5043:
- Part Number: 0720181
- Active Membrane Area: 70 ft² (6.5 m²)
- Fiber Inside Diameter: 43 mil (1.1 mm)
- WINEFILTER II 5060:
- Part Number: 0720217
- Active Membrane Area: 97 ft² (9.0 m²)
- Fiber Inside Diameter: 43 mil (1.1 mm)
Operating limits
- Recommended Inlet Pressure: 20-30 psi (1.4-2.1 bar)
- Maximum Transmembrane Pressure: 25 psi (1.7 bar)
- Maximum Feed Side Pressure Drop: 25 psi (1.7 bar)
- Maximum Backflush Pressure: 20 psi (1.4 bar)
- Maximum Operating Temperature: 104°F (40°C) @ pH 6
- Maximum Cleaning Temperature: 122°F (50°C)
- Allowable pH (Cleaning): 1.5 – 13.0 @ 104°F (40°C)
Consult KMS Industrial Process Technology Group for specific information.
Mechanical / hydraulic
Nominal Dimensions
- WINEFILTER II 5043:
- A: 43 inch (1,092 mm)
- B: 5.0 inch (127 mm)
- C: 38⁵⁄₈ inch (981 mm)
- D: 6.0 inch (152 mm)
- Permeate Connection: 1½” NPSM
- Process Connection: 6” NPSM
- WINEFILTER II 5060:
- A: 60 inch (1,524 mm)
- B: 5.0 inch (127 mm)
- C: 55⁵⁄₈ inch (1,413 mm)
- D: 6.0 inch (152 mm)
- Permeate Connection: 1½” NPSM
- Process Connection: 6” NPSM
Cartridge Hardware
- 5” HF Cartridge
- Process Cap Nut (KPN 0040364)
- Cartridge Gasket Silicon (KPN 0211095)
- Cartridge Reducing Elbow (KPN 0040365)
- Cartridge Straight adapter (threaded) (KPN 0040376)
- Manifold Gasket EPDM (KPN 0090439)
- Manifold Gasket BUNA (KPN 0090432)
- Cartridge Backup Ring (KPN 0040368)
- Manifold Cap Nut (KPN 0040367)
- Permeate Port Gasket (KPN 0090448)
- Permeate Plug (KPN 0040375)
- Permeate Adapter Sanitary (KPN 0211787)
- Permeate Cap Nut (for part 17) (KPN 0040377)
Lubricants
For cartridge installation, use only water or glycerin to lubricate seals. The use of petroleum or vegetable-based oils or solvents may damage the cartridge and will void the warranty.
Exposure to Chemical Oxidants
Exposure to chemical oxidants for thorough cleaning and sanitization may be necessary. Chemical oxidants commonly used in food applications include peracetic acid blends, hydrogen peroxide, and sodium hypochlorite. Consult KMS for recommended addition rates, frequency of use, and tolerance. Potassium metabisulfite (without catalyst such as cobalt) is the preferred chemical to eliminate residual chlorine or similar oxidizers prior to processing the feed stream.
Disclaimer: This summary is based on the provided text extract and may not include all figures, footnotes, or the latest revisions of the OEM PDF datasheet. For contractual data, please refer to the specific OEM PDF revision used on your project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.